Capital Tile, LLC.: OSHA inspections and violations

Kansas City, Missouri · Tile and Terrazzo Contractors · NAICS 238340

1inspections
2citation items
$1,440current penalties
Mar 22, 2016last inspection

Capital Tile, LLC. has one OSHA inspection on record in Missouri.

OSHA opened it on Mar 22, 2016, in Kansas City.

From that inspection OSHA issued 2 citation items: 2 serious.

OSHA proposed $2,358 in penalties. After settlements and reviews the total is $1,440, down 39%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Capital Tile, LLC. averages $1,440 over 1 cited inspection in that time.

Capital Tile, LLC.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Capital Tile, LLC. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341347938 OPENED MAR 22, 2016Closed

Unprogrammed other · Complete · Safety · 3 employees at the site · Closed May 3, 2016

6420 Nw Barry Road, Kansas City, MO 64154 · Tile and Terrazzo Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$1,440$1,440Mar 30, 2016Final
Citation 1, item 1b
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$918$0Mar 30, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(a)(2)(ii)(i)

(iii) Guarding. For temporary wiring over 600 volts, nominal, fencing, barriers, or other effective means shall be provided to prevent access of other than authorized and qualified personnel.

Other tile and terrazzo contractors employers in Missouri

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.