OSHA has inspected Capitol Building Supply, Inc. 7 times in Maryland since 2008.

The latest one began on May 22, 2024 after an accident, in Gaithersburg.

Those inspections ended with 10 citation items: 2 serious and 8 other-than-serious.

Penalties were first proposed at $7,200 and now stand at $3,920, 46% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 2 items under 1910.305.

How that compares: the median penalty per cited inspection for retail employers since 2015 is $1,750, and Capitol Building Supply, Inc. averages $1,620 (1 cited inspection).

Capitol Building Supply, Inc. also files yearly injury logs with OSHA, summarized below.

Capitol Building Supply, Inc.: OSHA citation items per year, 2008 to 2024
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

189employers cited

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Capitol Building Supply, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347503245 OPENED MAY 22, 2024Closed

Accident · Partial · Safety · 3 employees at the site · Closed Jun 25, 2024

9552 Nature Trail Lot# 415b, Gaithersburg, MD 20877 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 345831028 OPENED MAR 11, 2022Closed

Accident · Partial · Safety · 3 employees at the site · Closed Apr 8, 2022

1613 Lee Drive, Edgewater, MD 21037 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343366084 OPENED AUG 6, 2018Closed

Planned · Complete · Safety · 3 employees at the site · Closed Oct 12, 2018

7841 Chanceford Drive Parkside By Ryan Homes, Hanover, MD 21076 · Brick, Stone, and Related Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342023819 OPENED JAN 12, 2017Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 19, 2017

Swan Comb Loop, Upper Marlboro, MD 20772 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Other-than-serious$2,700$1,620Apr 4, 2017Final

Inspection 339980856 OPENED SEP 17, 2014Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 17, 2014

7601 Baltimore Avenue, College Park, MD 20740 · Brick, Stone, and Related Construction Material Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316689660 OPENED OCT 4, 2012Closed

Planned · Complete · Safety · 20 employees at the site · Closed Jan 10, 2013

700 E First Street, Hagerstown, MD 21740 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(5) · Machine guarding
Serious$2,250$1,150Dec 3, 2012Closed
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$2,250$1,150Dec 3, 2012Closed
Citation 2, item 1
29 CFR 1910.29(a)(4)(ii) · Manually propelled mobile ladder stands and scaffolds (towers)
Other-than-serious$0$0Dec 3, 2012Closed
Citation 2, item 2
29 CFR 1910.303(g)(2)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Dec 3, 2012Closed
Citation 2, item 3
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 3, 2012Closed
Citation 2, item 4
29 CFR 50405 B02
Other-than-serious$0$0Dec 3, 2012Closed
Citation 2, item 5
29 CFR 50405 D
Other-than-serious$0$0Dec 3, 2012Closed

Inspection 312947591 OPENED DEC 30, 2008Closed

Planned · Complete · Health · 17 employees at the site · Closed Mar 19, 2009

700 East First Street, Hagerstown, MD 21740 · Home Centers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 50405 B01
Other-than-serious$0$0Jan 14, 2009Closed
Citation 1, item 2
29 CFR 50406 A01
Other-than-serious$0$0Jan 14, 2009Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Upper Marlboro site logged 0 recordable injuries or illnesses among about 57 workers: 0.0 per 100 full-time workers, against a median of 3.5 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
CBSI Forestville
Upper Marlboro · 2025
57 000.03.5
CBSI Gaithersburg
Gaithersburg · 2025
32 000.03.5
CBSI Hagerstown
Hagerstown · 2025
23 000.03.5
CBSI Forestville
Upper Marlboro · 2024
61 416.43.5
CBSI Gaithersburg
Gaithersburg · 2024
33 216.23.5
CBSI Hagerstown
Hagerstown · 2024
26 209.23.5
CBSI - Forestville
Upper Marlboro · 2019
68 303.73.5
CBSI - Gaithersburg
Gaithersburg · 2019
27 216.33.5

Included with any plan: 8 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(5)

(5) Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half ( 1/2) inch.

29 CFR 1910.29 · Manually propelled mobile ladder stands and scaffolds (towers)

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(2)(ii)

(ii) In locations where electric equipment is likely to be exposed to physical damage, enclosures or guards shall be so arranged and of such strength as to prevent such damage.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(1)(ii)

(ii) Unused openings in cabinets, boxes, and fittings shall be effectively closed.

29 CFR 1926.501 · Fall protection in construction