OSHA SearchOSHA records by employer

Capstone Constructors Corp.: OSHA inspections and violations

Phoenix, Arizona · Commercial and Institutional Building Construction · NAICS 236220

7inspections
21citation items
$5,662current penalties
Jan 14, 2019last inspection

OSHA has inspected Capstone Constructors Corp. 7 times in Arizona since 1991.

The latest one began on Jan 14, 2019 on a referral, in Phoenix.

Those inspections ended with 21 citation items: 13 serious and 8 other-than-serious.

Penalties were first proposed at $9,450 and now stand at $5,662, 40% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,078, and Capstone Constructors Corp. averages $1,150 (2 cited inspections).

Capstone Constructors Corp.: OSHA citation items per year, 1991 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites Capstone Constructors Corp. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343728689 OPENED JAN 14, 2019Closed

Referral · Partial · Safety · 5 employees at the site · Closed Aug 2, 2019

3455 W Mcdowell Rd., Phoenix, AZ 85009 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$625$500Jul 9, 2019Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,000$800Jul 9, 2019Final

Inspection 341934206 OPENED NOV 22, 2016Closed

Referral · Partial · Safety · 6 employees at the site · Closed Jan 25, 2017

3250 E Andy Devine Ave, Kingman, AZ 86401 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$1,000$1,000Dec 13, 2016Final

Inspection 340085612 OPENED NOV 6, 2014Closed

Complaint · Partial · Safety · 8 employees at the site · Closed May 11, 2015

620 E Carefree Hwy, Phoenix, AZ 85085 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$750$562Feb 2, 2015Final
Citation 1, item 1b
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$0$0Feb 2, 2015Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Feb 2, 2015Final
Citation 1, item 1d
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 2, 2015Final
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$750$562Feb 2, 2015Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$750$562Feb 2, 2015Final
Citation 2, item 1
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Other-than-serious$0$0Feb 2, 2015Final

Inspection 308283183 OPENED OCT 25, 2004Closed

Planned · Complete · Safety · 5 employees at the site · Closed Mar 29, 2005

2160 East Highway 89a, Cottonwood, AZ 86326 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$750Dec 23, 2004Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$750Dec 23, 2004Closed
Citation 1, item 3
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$1,500$100Dec 23, 2004Closed
Citation 2, item 1
29 CFR 1926.100(a) · Hard hats in construction
Other-than-serious$0$0Dec 23, 2004Closed
Citation 2, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Dec 23, 2004Closed

Inspection 306770843 OPENED MAY 30, 2003Closed

Planned · Complete · Safety · 3 employees at the site · Closed May 30, 2003

9050 West Thomas Road, Phoenix, AZ 85037 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108121526 OPENED MAY 2, 1991Closed

Planned · Complete · Safety · 1 employee at the site · Closed May 24, 1991

2350 Miracle Mile Rd Suite 100, Bullhead City, AZ 86442 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108125469 OPENED APR 18, 1991Closed

Planned · Complete · Safety · 16 employees at the site · Closed Jun 28, 1991

2350 Miracle Mile Rd Suite 100, Bullhead City, AZ 86442 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.51(a)(4) · Sanitation
Serious$75$75May 10, 1991Closed
Citation 2, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0May 10, 1991Closed
Citation 2, item 2
29 CFR 1926.59(g)(8) · Hazard communication
Other-than-serious$0$0May 10, 1991Closed
Citation 2, item 3
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0May 10, 1991Closed
Citation 2, item 4
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Other-than-serious$0$0May 10, 1991Closed
Citation 2, item 5
29 CFR R4130631 A
Other-than-serious$0$0May 10, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.51 · Sanitation

29 CFR 1926.59 · Hazard communication

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other commercial and institutional building construction employers in Arizona