OSHA SearchOSHA records by employer

Capstone Masonry, Inc.: OSHA inspections and violations

Tucson, Arizona · Masonry Contractors · NAICS 238140

4inspections
6citation items
$375current penalties
Feb 5, 2020last inspection

Since 2011, OSHA inspectors have visited Capstone Masonry, Inc. in Arizona 4 times.

The most recent inspection opened on Feb 5, 2020 as a planned inspection, in Tucson.

In all, OSHA issued 6 citation items: 1 serious and 5 other-than-serious.

The penalties, $375 in total, stand where OSHA first set them.

The rule cited most here is 1910.134 (respiratory protection), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Capstone Masonry, Inc. averages $0 across 1 cited inspection.

Capstone Masonry, Inc.: OSHA citation items per year, 2011 to 2020
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

92employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Capstone Masonry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344618004 OPENED FEB 5, 2020Closed

Planned · Complete · Safety · 2 employees at the site · Closed Aug 4, 2020

9300 E. Valencia Rd, Tucson, AZ 85747 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341305100 OPENED FEB 11, 2016Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jul 7, 2016

8323 N Shannon Rd., Tucson, AZ 85741 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jun 2, 2016Final
Citation 1, item 2
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Jun 2, 2016Final
Citation 1, item 3
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$0$0Jun 2, 2016Final

Inspection 316343250 OPENED JAN 26, 2012Closed

Accident · Partial · Health · 9 employees at the site · Closed May 2, 2012

1925 W River Rd, Tucson, AZ 85704 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jan 26, 2012: Employee is injured in fall from scaffold

On January 26, 2012, Employee # 1 was performing masonry work on a scaffold. Em ployee # 1 lost his balance and fell approximately 22 feet to the dirt surface. Employee # 1 suffered a fractured pelvis and injured his back.

No citations from this inspection.

Inspection 315978015 OPENED SEP 6, 2011Closed

Unprogrammed related · Complete · Safety · 10 employees at the site · Closed Dec 8, 2011

1925 W River Rd, Tucson, AZ 85719 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$375$375Oct 5, 2011Closed
Citation 2, item 1
29 CFR 1926.404(f)(6)(i) · Ground-fault protection on job sites
Other-than-serious$0$0Oct 5, 2011Closed
Citation 2, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Oct 5, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(h)(3)(iv)

(iv) The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(1)

(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.416 · Electrical safety in construction

Other masonry contractors employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.