Inspection 346820624 OPENED JUL 11, 2023Closed
45449 Severn Way, Sterling, VA 20166 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1990, OSHA inspectors have visited Cardinal Bakery Inc in Virginia 8 times.
The most recent inspection opened on Jul 11, 2023 as a planned inspection, in Sterling.
In all, OSHA issued 27 citation items: 19 serious and 8 other-than-serious.
The proposed penalties came to $14,820; today they stand at $12,779, 14% less.
The rule cited most here is 1910.1200 (hazard communication), 9 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,875 penalty. Cardinal Bakery Inc averages $3,192 across 2 cited inspections.
Virginia · latest 90 days of OSHA records
248employers cited
Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Virginia
Checking a subcontractor, a client or your own company? Watch Cardinal Bakery Inc and get notified the morning OSHA posts a new citation for it.
Watch this company45449 Severn Way, Sterling, VA 20166 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
22704 Commerce Center Court Suite 100, Sterling, VA 20166 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,975 | $1,975 | Apr 9, 2019 | Final |
| Citation 1, item 1b 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Apr 9, 2019 | Final |
| Citation 2, item 1 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Other-than-serious | $0 | $0 | Apr 9, 2019 | Final |
22704 Commerce Center Court, Sterling, VA 20166 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $2,205 | $2,205 | Nov 5, 2015 | Final |
| Citation 1, item 2a 29 CFR 1910.212(a)(2) · Machine guarding |
Serious | $2,205 | $2,205 | Nov 5, 2015 | Final |
| Citation 1, item 2b 29 CFR 1910.334(a)(2)(ii) · Using electrical equipment |
Serious | $0 | $0 | Nov 5, 2015 | Final |
45449 Severn Way, Sterling, VA 20166 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $735 | $514 | Jan 9, 2013 | Closed |
| Citation 1, item 1b 29 CFR 1910.1200(g)(1) · Hazard communication |
Serious | $0 | $0 | Jan 9, 2013 | Closed |
| Citation 1, item 1c 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Jan 9, 2013 | Closed |
45449 Severn Way, Sterling, VA 20166 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(1) · Permit-required confined spaces |
Serious | $1,250 | $1,250 | Sep 12, 2008 | Closed |
| Citation 1, item 2 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $1,000 | $1,000 | Sep 12, 2008 | Closed |
| Citation 2, item 1 29 CFR 1910.147(c)(1) · Lockout/tagout |
Other-than-serious | $0 | $0 | Sep 12, 2008 | Closed |
| Citation 2, item 2 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 12, 2008 | Closed |
45449 Severn Way, Suite 190, Sterling, VA 20166 · Commercial Bakeries · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(b) · First aid and eyewash |
Serious | $1,225 | $735 | Jun 9, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $875 | $525 | Jun 9, 2003 | Closed |
| Citation 1, item 3a 29 CFR 1910.263(c)(2) · Bakery equipment |
Serious | $875 | $525 | Jun 9, 2003 | Closed |
| Citation 1, item 3b 29 CFR 1910.263(c)(3) · Bakery equipment |
Serious | $0 | $0 | Jun 9, 2003 | Closed |
| Citation 1, item 4 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $875 | $525 | Jun 9, 2003 | Closed |
| Citation 1, item 5 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $700 | $420 | Jun 9, 2003 | Closed |
21673 Beaumeade Circle, Suite 320, Ashburn, VA 22011 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
21673 Beaumeade Circle, Suite 320, Ashburn, VA 22011 · OSHA's record · Phone and website on Google Maps
Incident on Oct 4, 1990: Employee's finger partially amputated in machine
Employee #1 was cleaning a divider that had an access door. The window was missi ng in the access door. The access door was equipped with a limit switch to cut o ff the power when the door was open. Employee #1 reached through the window open ing without opening the door to retrieve a piece of dough. He caught his fingern ail and shifted his position, leaned against the machine's START button, and ina dvertently activated the machine. The machine amputated a portion of Employee #1 's left middle finger.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $300 | $300 | Nov 16, 1990 | Closed |
| Citation 1, item 2 29 CFR 1910.263(c)(3) · Bakery equipment |
Serious | $300 | $300 | Nov 16, 1990 | Closed |
| Citation 1, item 3 29 CFR 1910.263(f)(3) · Bakery equipment |
Serious | $300 | $300 | Nov 16, 1990 | Closed |
| Citation 2, item 1 29 CFR ARM001101 A |
Other-than-serious | $0 | $0 | Nov 16, 1990 | Closed |
| Citation 2, item 2 29 CFR ARM001103 A |
Other-than-serious | $0 | $0 | Nov 16, 1990 | Closed |
| Citation 2, item 3 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 16, 1990 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(g)(8) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 16, 1990 | Closed |
| Citation 2, item 5 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 16, 1990 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(g)(1)
(g) Safety data sheets. (1) Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.
29 CFR 1910.1200(g)(8)
(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)
Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.