OSHA SearchOSHA records by employer

Caribou Utilities District: OSHA inspections and violations

Caribou, Maine · Water Supply and Irrigation Systems · NAICS 221310

1inspections
4citation items
$0current penalties
Jul 20, 2017last inspection

Caribou Utilities District has one OSHA inspection on record in Maine.

OSHA opened it on Jul 20, 2017, in Caribou.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Caribou Utilities District averages $0 over 1 cited inspection in that time.

Caribou Utilities District: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Maine · latest 90 days of OSHA records

34employers cited

Get notified the morning OSHA posts each new citation in Maine: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maine

Checking a subcontractor, a client or your own company? Watch Caribou Utilities District and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342486016 OPENED JUL 20, 2017Closed

Programmed other · Partial · Safety · Local government · 9 employees at the site · Closed Oct 25, 2017

176 Limestone St, Caribou, ME 04736 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.303(g)(2)(i)(d) · Electrical equipment, general requirements
Serious$0$0Oct 13, 2017Final
Citation 1, item 1b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Oct 13, 2017Final
Citation 1, item 2
29 CFR 1910.28(b)(11)(ii) · Fall protection in general industry
Serious$0$0Oct 13, 2017Final
Citation 1, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Serious$0$0Oct 13, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.28(b)(11)(ii)

(ii) Each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as follows:

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(f)(2)

(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.

29 CFR 1910.303(g)(2)(i)

(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:

Other water supply and irrigation systems employers in Maine

Alert subscribers get notified of each newly cited employer in Maine the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.