OSHA SearchOSHA records by employer

Carlson Testing Inc: OSHA inspections and violations

Tigard, Oregon · Testing Laboratories and Services · NAICS 541380

7inspections
22citation items
$1,800current penalties
Jul 6, 2022last inspection

OSHA has inspected Carlson Testing Inc 7 times in Oregon since 2003.

The latest one began on Jul 6, 2022 after a complaint, in Tigard.

Those inspections ended with 22 citation items: 9 serious and 13 other-than-serious.

Penalties were first proposed at $1,800 and still stand at $1,800.

comes up most often in these citations: 7 items under 7010.7650.

How that compares: the median penalty per cited inspection for professional services employers since 2015 is $1,821, and Carlson Testing Inc averages $0 (2 cited inspections).

Carlson Testing Inc: OSHA citation items per year, 2003 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Carlson Testing Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346079205 OPENED JUL 6, 2022Closed

Complaint · Partial · Health · 104 employees at the site · Closed Apr 25, 2023

8430 Sw Hunziker St #100, Tigard, OR 97223 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-002-1059(2)
Other-than-serious$0$0Oct 27, 2022Final

Inspection 345730154 OPENED JAN 14, 2022Closed

Complaint · Partial · Health · 54 employees at the site · Closed Jun 8, 2022

8430 Sw Hunziker Rd #100, Portland, OR 97223 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 18, 2022Final

Inspection 315422683 OPENED MAR 29, 2011Closed

Planned · Complete · Safety · 100 employees at the site · Closed Jul 21, 2011

321 1st St, Gearhart, OR 97138 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313461519 OPENED NOV 19, 2009Closed

Planned · Complete · Safety · 12 employees at the site · Closed Nov 19, 2009

3840 Nw Bus Evans Ln, Prineville, OR 97754 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310684287 OPENED FEB 9, 2007Closed

Planned · Complete · Safety · 110 employees at the site · Closed Jun 15, 2007

8430 Sw Hunziker St #100, Tigard, OR 97223 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.243(c)(1) · Guarding of portable powered tools
Serious$195$195Mar 5, 2007Closed
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 5, 2007Closed
Citation 2, item 3 Other-than-serious$0$0Mar 5, 2007Closed
Citation 2, item 4
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Other-than-serious$0$0Mar 5, 2007Closed

Inspection 306469685 OPENED JAN 20, 2004Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jun 14, 2004

4060 Hudson Ave Ne, Salem, OR 97301 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$195$195Feb 13, 2004Closed
Citation 2, item 2
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Feb 13, 2004Closed
Citation 2, item 3 Other-than-serious$0$0Feb 13, 2004Closed
Citation 2, item 4 Other-than-serious$0$0Feb 13, 2004Closed
Citation 2, item 5 Other-than-serious$0$0Feb 13, 2004Closed
Citation 2, item 6 Other-than-serious$0$0Feb 13, 2004Closed
Citation 2, item 7
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Feb 13, 2004Closed

Inspection 305583254 OPENED MAR 7, 2003Closed

Planned · Complete · Safety · 130 employees at the site · Closed Jul 15, 2003

8430 Hunziker St, Tigard, OR 97223 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$300$300Apr 9, 2003Closed
Citation 1, item 1b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Apr 9, 2003Closed
Citation 1, item 2 Serious$300$300Apr 9, 2003Closed
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$300$300Apr 9, 2003Closed
Citation 1, item 4 Serious$210$210Apr 9, 2003Closed
Citation 1, item 5a Serious$300$300Apr 9, 2003Closed
Citation 1, item 5b Serious$0$0Apr 9, 2003Closed
Citation 2, item 6
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Apr 9, 2003Closed
Citation 2, item 7
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Apr 9, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)(i)

(i) A list of the hazardous chemicals known to be present using a product identifier that is referenced on the appropriate safety data sheet (the list may be compiled for the workplace as a whole or for individual work areas); and,

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.305 · Electrical wiring methods

29 CFR 7010.7650

29 CFR 7020.2231

29 CFR 7020.2900

Other testing laboratories and services employers in Oregon

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.