Inspection 347622326 OPENED JUL 16, 2024Closed
100 Tarentum Bridge Road, New Kensington, PA 15068 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pittsburgh, Pennsylvania · Commercial and Institutional Building Construction · NAICS 236220
Since 2022, OSHA inspectors have visited Cartel Demo, LLC in Pennsylvania 2 times.
The most recent inspection opened on Jul 16, 2024 after a complaint, in New Kensington.
In all, OSHA issued 4 citation items: 4 serious.
The proposed penalties came to $4,972; today they stand at $2,496, 50% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Cartel Demo, LLC averages $2,496 across 1 cited inspection.
Pennsylvania · latest 90 days of OSHA records
280employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Cartel Demo, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company100 Tarentum Bridge Road, New Kensington, PA 15068 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4778 Mcknight Road, Pittsburgh, PA 15237 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.451(b)(1)(ii) · Scaffolds, general requirements |
Serious | $2,486 | $1,248 | Nov 4, 2022 | Final |
| Citation 1, item 1b 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $0 | $0 | Nov 4, 2022 | Final |
| Citation 1, item 2a 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $2,486 | $1,248 | Nov 4, 2022 | Final |
| Citation 1, item 2b 29 CFR 1926.454(b) · Scaffold training |
Serious | $0 | $0 | Nov 4, 2022 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)(ii)
(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 9 1/2 inches (24.1 cm).
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(g)(4)(i)
(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.