OSHA SearchOSHA records by employer

Cartrust, LLC: OSHA inspections and violations

Tampa, Florida · Ornamental and Architectural Metal Work Manufacturing · NAICS 332323

1inspections
4citation items
$8,239current penalties
Apr 3, 2017last inspection

OSHA has inspected Cartrust, LLC once in Florida.

The inspection began on Apr 3, 2017 after a complaint, in Tampa.

That inspection ended with 4 citation items: 3 serious and 1 other-than-serious.

Penalties were first proposed at $16,478 and now stand at $8,239, 50% lower after settlements or reviews.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Cartrust, LLC averages $8,239 (1 cited inspection).

Cartrust, LLC: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Cartrust, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342221132 OPENED APR 3, 2017Closed

Complaint · Partial · Health · 32 employees at the site · Closed Dec 4, 2017

11302 North Nebraska Ave, Tampa, FL 33612 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$5,070$2,535Oct 2, 2017Final
Citation 1, item 2
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$5,070$2,535Oct 2, 2017Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$6,338$3,169Oct 2, 2017Final
Citation 2, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 2, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.151(c)

(c) Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(h)(1)

(h) Radial saws. (1) The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will deflect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)

(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

29 CFR 1910.334 · Using electrical equipment

Other ornamental and architectural metal work manufacturing employers in Florida

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.