Inspection 343941787 OPENED APR 18, 2019Closed
148 Hudson River Road, Waterford, NY 12188 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Cascades Tissue Group - New York Inc. has 2 OSHA inspections on record in New York, the first in 2015.
OSHA's last visit started on Apr 18, 2019 after a complaint, in Waterford.
Across those inspections OSHA issued 5 citation items: 5 serious.
OSHA proposed $28,000 in penalties. After settlements and reviews the total is $10,500, down 62%.
Most often, OSHA cited 1910.147, lockout/tagout (4 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Cascades Tissue Group - New York Inc. averages $10,500 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
376employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Cascades Tissue Group - New York Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company148 Hudson River Road, Waterford, NY 12188 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
148 Hudson River Road, Waterford, NY 12188 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $7,000 | $5,250 | Jul 27, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(4)(ii)(b) · Lockout/tagout |
Serious | $7,000 | $5,250 | Jul 27, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $7,000 | $0 | Jul 27, 2015 | Final |
| Citation 1, item 5a 29 CFR 1910.261(b)(1) · Pulp, paper, and paperboard mills |
Serious | $7,000 | $0 | Jul 27, 2015 | Final |
| Citation 1, item 5b 29 CFR 1910.147(c)(5)(ii)(d) · Lockout/tagout |
Serious | $0 | $0 | Jul 27, 2015 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(4)(ii)(b)
(B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;
29 CFR 1910.147(c)(5)(ii)(d)
(D) Identifiable. Lockout devices and tagout devices shall indicate the identity of the employee applying the device(s).
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.