OSHA SearchOSHA records by employer

Casper Electric Inc: OSHA inspections and violations

Casper, Wyoming · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

12inspections
13citation items
$1,418current penalties
Apr 4, 2019last inspection

Casper Electric Inc has 12 OSHA inspections on record in Wyoming, the first in 1987.

OSHA's last visit started on Apr 4, 2019 on a referral, in Rock Springs.

Across those inspections OSHA issued 13 citation items: 3 serious and 10 other-than-serious.

OSHA proposed $8,447 in penalties. After settlements and reviews the total is $1,418, down 83%.

Most often, OSHA cited 1926.405, job-site wiring (5 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Casper Electric Inc averages $0 over 1 cited inspection in that time.

Casper Electric Inc: OSHA citation items per year, 1987 to 2019
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Casper Electric Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343916029 OPENED APR 4, 2019Closed

Referral · Partial · Safety · 55 employees at the site · Closed Dec 15, 2023

Center & Grant St, Rock Springs, WY 82901 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.251(d)(6) · Rigging equipment for material handling
Serious$5,497$0Jun 13, 2019Final

Inspection 341748226 OPENED AUG 25, 2016Closed

Planned · Partial · Safety · 90 employees at the site · Closed Aug 25, 2016

3500 E 12th St, Casper, WY 82609 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 312202302 OPENED MAR 3, 2009Closed

Planned · Complete · Safety · 50 employees at the site · Closed May 29, 2009

2900 Cyclone, Casper, WY 82604 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Other-than-serious$0$0Apr 28, 2009Closed

Inspection 309498004 OPENED MAR 27, 2007Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Jul 2, 2007

5905 Cy Ave, Casper, WY 82601 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0May 23, 2007Closed
Citation 1, item 2
29 CFR 1926.403(e) · Electrical equipment on job sites
Other-than-serious$0$0May 23, 2007Closed
Citation 1, item 3
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0May 23, 2007Closed

Inspection 309494987 OPENED JUN 20, 2006Closed

Planned · Complete · Safety · 31 employees at the site · Closed Sep 28, 2006

300 Southwest Wyoming Blvd., Mills, WY 82644 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Unclassified$875$218Aug 31, 2006Closed
Citation 2, item 1
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Aug 31, 2006Closed
Citation 2, item 2
29 CFR 1926.403(h) · Electrical equipment on job sites
Other-than-serious$0$0Aug 31, 2006Closed

Inspection 307818948 OPENED FEB 28, 2006Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 13, 2006

301 Lathrop Road, Evansville, WY 82636 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR PP040004 CII D2
Other-than-serious$0$0Mar 30, 2006Closed
Citation 2, item 1
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Other-than-serious$875$0Mar 30, 2006Closed

Inspection 303669626 OPENED JUN 19, 2002Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 17, 2002

1401 Wilkins Circle, Casper, WY 82601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(iii) · Job-site wiring
Other-than-serious$0$0Jun 19, 2002Closed

Inspection 125181784 OPENED AUG 25, 1999Closed

Planned · Complete · Safety · 18 employees at the site · Closed Sep 28, 1999

Billboard Adjacent To I-25, Casper, WY 82601 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$600$600Sep 2, 1999Closed
Citation 1, item 2 Serious$600$600Sep 2, 1999Closed
4 older inspections

Inspection 114631930 OPENED OCT 9, 1991Closed

Planned · Complete · Safety · 7 employees at the site · Closed Oct 14, 1991

1st & Conwell, Casper, WY 82601 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 114635196 OPENED AUG 28, 1991Closed

Planned · Complete · Safety · 5 employees at the site · Closed Sep 3, 1991

Casper Petroleum Club, Casper, WY 82601 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 107860918 OPENED DEC 4, 1990Closed

Planned · Complete · Safety · 5 employees at the site · Closed Dec 10, 1990

Wyoming Medical Center, Casper, WY 82601 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105798144 OPENED FEB 26, 1987Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 2, 1987

301 S. Wolcott, Casper, WY 82601 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.251 · Rigging equipment for material handling

29 CFR 1926.251(d)(6)

(6) Removal from service. Natural and synthetic fiber rope slings shall be immediately removed from service if any of the following conditions are present:

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.403(e)

(e) Splices. Conductors shall be spliced or joined with splicing devices designed for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be so spliced or joined as to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device designed for the purpose.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.556

Other electrical contractors and other wiring installation contractors employers in Wyoming

Alert subscribers get notified of each newly cited employer in Wyoming the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.