Casto Construction: OSHA inspections and violations

Delaware, Ohio · New Multifamily Housing Construction (except For-Sale Builders) · NAICS 236116

4inspections
11citation items
$18,757current penalties
Aug 2, 2016last inspection

OSHA has inspected Casto Construction 4 times in Ohio since 2003.

The latest one began on Aug 2, 2016 as a planned inspection, in Dublin.

Those inspections ended with 11 citation items: 11 serious.

Penalties were first proposed at $29,991 and now stand at $18,757, 37% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Casto Construction averages $11,545 (1 cited inspection).

Casto Construction: OSHA citation items per year, 2003 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Casto Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341667863 OPENED AUG 2, 2016Closed

Planned · Complete · Safety · 200 employees at the site · Closed Oct 21, 2016

4313 Tuller Road, Dublin, OH 43017 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Serious$8,017$4,810Sep 23, 2016Final
Citation 1, item 1b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Sep 23, 2016Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$11,224$6,734Sep 23, 2016Final

Inspection 309177806 OPENED AUG 11, 2005Closed

Planned · Complete · Safety · 70 employees at the site · Closed Sep 7, 2005

328 Damascus Road, Marysville, OH 43040 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(a)(2)(ii) · Job-site wiring
Serious$1,125$788Aug 22, 2005Closed
Citation 1, item 2
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$900$630Aug 22, 2005Closed
Citation 1, item 3
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,125$788Aug 22, 2005Closed
Citation 1, item 4
29 CFR 1926.454(a) · Scaffold training
Serious$1,125$788Aug 22, 2005Closed

Inspection 307886663 OPENED DEC 14, 2004Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jan 25, 2005

2339 Taylor Road, Reynoldsburg, OH 43068 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.153(o) · Liquefied petroleum gas (LP-Gas)
Serious$225$158Dec 21, 2004Closed

Inspection 306540337 OPENED AUG 25, 2003Closed

Planned · Complete · Safety · 4 employees at the site · Closed Oct 6, 2003

124 Lippazon Way, Delaware, OH 43015 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$1,375$894Sep 5, 2003Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,500$2,275Sep 4, 2003Closed
Citation 1, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,375$894Sep 4, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.153 · Liquefied petroleum gas (LP-Gas)

29 CFR 1926.153(o)

(o) Damage from vehicles. When damage to LP-Gas systems from vehicular traffic is a possibility, precautions against such damage shall be taken.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

Other new multifamily housing construction (except for-sale builders) employers in Ohio

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.