OSHA SearchOSHA records by employer

Caststone, LLC.: OSHA inspections and violations

Pigeon Forge, Tennessee · Masonry Contractors · NAICS 238140

2inspections
7citation items
$2,700current penalties
Aug 29, 2017last inspection

OSHA has inspected Caststone, LLC. 2 times in Tennessee since 2012.

The latest one began on Aug 29, 2017 as a planned inspection, in Knoxville.

Those inspections ended with 7 citation items: 1 repeat and 6 other-than-serious.

Penalties were first proposed at $2,700 and still stand at $2,700.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Caststone, LLC. averages $2,700 (1 cited inspection).

Caststone, LLC.: OSHA citation items per year, 2012 to 2017
Citation items per year, by inspection date.

Want to know if OSHA cites Caststone, LLC. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 342597333 OPENED AUG 29, 2017Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 22, 2018

400 Herron Rd., Knoxville, TN 37934 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$200$200Dec 14, 2017Final
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Other-than-serious$0$0Dec 14, 2017Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$0$0Dec 14, 2017Final
Citation 1, item 2a
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Other-than-serious$100$100Dec 14, 2017Final
Citation 1, item 2b
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0Dec 14, 2017Final
Citation 2, item 1
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Repeat$2,400$2,400Dec 14, 2017Final

Inspection 316719707 OPENED AUG 30, 2012Closed

Planned · Complete · Safety · 6 employees at the site · Closed Oct 8, 2012

135 Jake Thomas Road, Pigeon Forge, TN 37843 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Other-than-serious$0$0Sep 27, 2012Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Tennessee

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.