Castulo Stucco & Masonry: OSHA inspections and violations

Lewisville, Texas · Masonry Contractors · NAICS 238140

1inspections
3citation items
$6,940current penalties
Oct 2, 2020last inspection

OSHA inspectors have visited Castulo Stucco & Masonry in Texas one time.

It opened on Oct 2, 2020 as a planned inspection, in Lewisville.

In all, OSHA issued 3 citation items: 3 serious.

The penalties, $6,940 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Castulo Stucco & Masonry averages $6,940 across 1 cited inspection.

Castulo Stucco & Masonry: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

401employers cited

14 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Castulo Stucco & Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344954805 OPENED OCT 2, 2020Closed

Planned · Partial · Safety · 1 employee at the site · Closed Mar 8, 2023

3901 Gidar, Lewisville, TX 75067 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,048$4,048Oct 5, 2020Final
Citation 1, item 1b
29 CFR 1926.451(f)(15) · Scaffolds, general requirements
Serious$0$0Oct 5, 2020Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$2,892$2,892Oct 5, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(f)(15)

(15) Ladders shall not be used on scaffolds to increase the working level height of employees, except on large area scaffolds where employers have satisfied the following criteria:

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.