Inspection 341202893 OPENED JAN 26, 2016Closed
2843 Sr 370, Cato, NY 13033 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Cato-Meridian CSD Recreation Center has 4 OSHA inspections on record in New York, the first in 2011.
OSHA's last visit started on Jan 26, 2016 to follow up on an earlier case, in Cato.
Across those inspections OSHA issued 6 citation items: 3 serious and 3 other-than-serious.
OSHA did not attach a penalty to any of these citations.
Most often, OSHA cited 1910.37, exit routes (3 items).
For context, across all education employers the median penalty per cited inspection since 2015 is $0. Cato-Meridian CSD Recreation Center averages $0 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
372employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Cato-Meridian CSD Recreation Center and get notified the morning OSHA posts a new citation for it.
Watch this company2843 Sr 370, Cato, NY 13033 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2843 Sr 370, Cato, NY 13033 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Dec 30, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.305(e)(1) · Electrical wiring methods |
Serious | $0 | $0 | Dec 30, 2015 | Final |
2843 Route 370, Cato, NY 13033 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
2843 Route 370, Cato, NY 13033 · Elementary and Secondary Schools · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods |
Serious | $0 | $0 | Feb 25, 2011 | Closed |
| Citation 2, item 1 29 CFR 1910.37(b)(2) · Exit routes |
Other-than-serious | $0 | $0 | Feb 25, 2011 | Closed |
| Citation 2, item 2 29 CFR 1910.37(b)(4) · Exit routes |
Other-than-serious | $0 | $0 | Feb 25, 2011 | Closed |
| Citation 2, item 3 29 CFR 1910.37(b)(5) · Exit routes |
Other-than-serious | $0 | $0 | Feb 25, 2011 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(f)(2)
(2) Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.
29 CFR 1910.305(e)(1)
(e) Enclosures for damp or wet locations—(1) Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures. Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations.
29 CFR 1910.305(g)(1)(iv)
(iv) Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used:
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.