Inspection 348691213 OPENED JAN 15, 2026Closed
701 South Harding Highway, Buena, NJ 08310 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Buena, New Jersey · Other Millwork (including Flooring) · NAICS 321918
Since 2026, OSHA inspectors have visited CBP Inc. in New Jersey 2 times.
The most recent inspection opened on Jan 15, 2026 on a referral, in Buena.
In all, OSHA issued 4 citation items: 4 serious.
The proposed penalties came to $11,585; today they stand at $7,300, 37% less.
The rule cited most here is 1910.303 (electrical equipment, general requirements), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. CBP Inc. averages $7,300 across 1 cited inspection.
Want to know if OSHA cites CBP Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company701 South Harding Highway, Buena, NJ 08310 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
701 South Harding Highway, Buena, NJ 08310 · Other Millwork (including Flooring) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.213(c)(1) · Woodworking machinery |
Serious | $4,965 | $3,300 | May 11, 2026 | Final |
| Citation 1, item 2a 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $6,620 | $4,000 | May 11, 2026 | Final |
| Citation 1, item 2b 29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | May 11, 2026 | Final |
| Citation 1, item 2c 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | May 11, 2026 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.213(c)(1)
(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po
29 CFR 1910.303(b)(2)
(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.
29 CFR 1910.303(b)(7)(i)
(i) Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.