OSHA SearchOSHA records by employer

Cca Restoration Inc.: OSHA inspections and violations

Frankfort, Illinois · Finish Carpentry Contractors · NAICS 238350

1inspections
5citation items
$4,320current penalties
Apr 15, 2015last inspection

OSHA has inspected Cca Restoration Inc. once in Illinois.

The inspection began on Apr 15, 2015 as a planned inspection, in Frankfort.

That inspection ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $6,000 and now stand at $4,320, 28% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 2 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Cca Restoration Inc. averages $4,320 (1 cited inspection).

Cca Restoration Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

426employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Cca Restoration Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340556067 OPENED APR 15, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 3, 2015

211 W. Nebraska St., Frankfort, IL 60423 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$1,960May 28, 2015Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements
Serious$2,800$1,960May 28, 2015Final
Citation 1, item 2b
29 CFR 1926.452(k)(1) · Rules for each type of scaffold
Serious$0$0May 28, 2015Final
Citation 1, item 2c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0May 28, 2015Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$400$400Aug 7, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.451(g)(1)(i)

(i) Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system;

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training