CCT Enterprises Inc: OSHA inspections and violations
Auburn, Indiana · Metal Crown, Closure, and Other Metal Stamping (except Automotive) · NAICS 332119
1inspections
8citation items
$2,700current penalties
Dec 13, 2023last inspection
OSHA has inspected CCT Enterprises Inc once in Indiana.
The inspection began on Dec 13, 2023 after a complaint, in Auburn.
That inspection ended with 8 citation items: 8 serious.
Penalties were first proposed at $5,400 and now stand at $2,700, 50% lower after settlements or reviews.
Mechanical power presses comes up most often in these citations: 6 items under 1910.217.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and CCT Enterprises Inc averages $2,700 (1 cited inspection).
CCT Enterprises Inc also files yearly injury logs with OSHA, summarized below.
Citation items per year, by inspection date.
Indiana · latest 90 days of OSHA records
78employers cited
Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Auburn site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 2.7 for its industry.
Site and year
Workers
Cases
Days-away cases
Rate
Industry median
CCT Enterprises, LLC
Auburn · 2024
20
0
0
0.0
2.7
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(13) Control reliability. When required by paragraph (c)(5) of this section, the control system shall be constructed so that a failure within the system does not prevent the normal stopping action from being applied to the press when required, but does prevent initiation of a successive stroke until the failure is corrected. The failure shall be detectable by a simple test, or indicated by the control system. This requirement does not apply to those elements of the control system which have no effect on the protection against point of operation injuries.
29 CFR 1910.217(b)(14)(i)
(i) Be so constructed as to automatically prevent the activation of a successive stroke if the stopping time or braking distance deteriorates to a point where the safety distance being utilized does not meet the requirements set forth in paragraph (c)(3)(iii)(e) or (c)(3)(vii)(c) of this section. The brake monitor used with the Type B gate or movable barrier device shall be installed in a manner to detect slide top-stop overrun beyond the normal limit reasonably established by the employer.
29 CFR 1910.217(b)(7)(v)(b)
(v) Two-hand controls for single stroke shall conform to the following requirements:
29 CFR 1910.303 · Electrical equipment, general requirements
Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.