OSHA SearchOSHA records by employer

Celso Hernandez dba JCC Structures: OSHA inspections and violations

Greensboro, North Carolina · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
8citation items
$2,600current penalties
Aug 12, 2019last inspection

OSHA inspectors have visited Celso Hernandez dba JCC Structures in North Carolina one time.

It opened on Aug 12, 2019 as a planned inspection, in Greensboro.

In all, OSHA issued 8 citation items: 5 serious and 3 other-than-serious.

The penalties, $2,600 in total, stand where OSHA first set them.

The rule cited most here is 1926.501 (fall protection in construction), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Celso Hernandez dba JCC Structures averages $2,600 across 1 cited inspection.

Celso Hernandez dba JCC Structures: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

236employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Celso Hernandez dba JCC Structures and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344246160 OPENED AUG 12, 2019Closed

Planned · Complete · Safety · 2 employees at the site · Closed Nov 27, 2019

2503 Greengate Dr, Greensboro, NC 27406 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$1,000$1,000Oct 1, 2019Final
Citation 1, item 1b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Oct 1, 2019Final
Citation 1, item 2a
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,000$1,000Oct 1, 2019Final
Citation 1, item 2b
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$0$0Oct 1, 2019Final
Citation 1, item 3
29 CFR 1926.502(d)(21) · Fall protection systems
Serious$600$600Oct 1, 2019Final
Citation 2, item 1
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 2
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Oct 1, 2019Final
Citation 2, item 3
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Oct 1, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.25(a)

(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(f)(6)

(6) Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

Other new single-family housing construction (except for-sale builders) employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.