OSHA SearchOSHA records by employer

Central Gear Inc: OSHA inspections and violations

Madison Heights, Michigan · Machine Shops · NAICS 332710

6inspections
65citation items
$9,000current penalties
Sep 28, 2023last inspection

Since 1991, OSHA inspectors have visited Central Gear Inc in Michigan 6 times.

The most recent inspection opened on Sep 28, 2023 as a planned inspection, in Madison Heights.

In all, OSHA issued 65 citation items: 31 serious, 2 repeat and 32 other-than-serious.

The proposed penalties came to $19,000; today they stand at $9,000, 53% less.

The rule cited most here is 1910.1200 (hazard communication), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Central Gear Inc averages $600 across 2 cited inspections.

Central Gear Inc: OSHA citation items per year, 1991 to 2023
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

653employers cited

12 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Central Gear Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346998933 OPENED SEP 28, 2023Closed

Planned · Complete · Safety · 7 employees at the site · Closed Nov 28, 2023

540 Ajax Dr, Madison Heights, MI 48071 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.12154(5)
Other-than-serious$0$0Nov 1, 2023Final

Inspection 344698089 OPENED MAR 16, 2020Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jun 12, 2020

540 Ajax Dr, Madison Heights, MI 48071 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10716
Serious$400$200Apr 9, 2020Final
Citation 1, item 2
29 CFR 408.10727(1)
Serious$400$200Apr 9, 2020Final
Citation 1, item 3
29 CFR 408.10731(1)
Serious$400$200Apr 9, 2020Final
Citation 1, item 4
29 CFR 408.12635(1)
Serious$400$200Apr 9, 2020Final
Citation 1, item 5
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$400$200Apr 9, 2020Final
Citation 1, item 6a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$400$200Apr 9, 2020Final
Citation 1, item 6b
29 CFR 1910.147(c)(2)(iii) · Lockout/tagout
Serious$0$0Apr 9, 2020Final
Citation 2, item 1
29 CFR 408.12131(1)
Other-than-serious$0$0Apr 9, 2020Final
Citation 2, item 2
29 CFR 408.12622(2)
Other-than-serious$0$0Apr 9, 2020Final
Citation 2, item 3
29 CFR 408.13311(1)
Other-than-serious$0$0Apr 9, 2020Final
Citation 2, item 4
29 CFR 408.14965(1)
Other-than-serious$0$0Apr 9, 2020Final
Citation 2, item 5
29 CFR 1910.1200(f)(6) · Hazard communication
Other-than-serious$0$0Apr 9, 2020Final

Inspection 125030486 OPENED JAN 27, 1997Closed

Complaint · Partial · Safety · 16 employees at the site · Closed Oct 9, 1997

540 Ajax Dr, Madison Heights, MI 48071 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$800$400Mar 24, 1997Closed
Citation 1, item 2 Serious$800$400Mar 24, 1997Closed
Citation 1, item 3 Serious$600$300Mar 24, 1997Closed
Citation 1, item 4 Serious$600$0Mar 24, 1997Closed
Citation 1, item 5 Serious$800$400Mar 24, 1997Closed
Citation 1, item 6 Serious$600$0Mar 24, 1997Closed
Citation 1, item 7 Serious$600$300Mar 24, 1997Closed
Citation 1, item 8 Serious$600$0Mar 24, 1997Closed
Citation 1, item 9 Serious$600$300Mar 24, 1997Closed
Citation 1, item 10 Serious$600$300Mar 24, 1997Closed
Citation 1, item 11 Serious$800$400Mar 24, 1997Closed
Citation 1, item 12 Serious$800$400Mar 24, 1997Closed
Citation 1, item 13 Serious$600$300Mar 24, 1997Closed
Citation 1, item 14 Serious$600$0Mar 24, 1997Closed
Citation 1, item 15 Serious$600$300Mar 24, 1997Closed
Citation 1, item 16 Serious$800$400Mar 24, 1997Closed
Citation 1, item 17 Serious$600$300Mar 24, 1997Closed
Citation 1, item 18
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$600$300Mar 24, 1997Closed
Citation 2, item 1 Repeat$1,600$800Mar 24, 1997Closed
Citation 2, item 2 Repeat$1,600$800Mar 24, 1997Closed
Citation 3, item 1 Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 2 Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 3 Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 4 Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 5
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 6 Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 7 Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 8 Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 9
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Mar 24, 1997Closed
Citation 3, item 10
29 CFR 1910.1200(f)(1) · Hazard communication
Other-than-serious$0$0Mar 24, 1997Closed

Inspection 125099655 OPENED NOV 29, 1995Closed

Planned · Complete · Safety · 23 employees at the site · Closed Jan 17, 1996

540 Ajax Dr, Madison Heights, MI 48071 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$350$350Dec 19, 1995Closed
Citation 1, item 2 Serious$150$150Dec 19, 1995Closed
Citation 1, item 3
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$150$150Dec 19, 1995Closed
Citation 1, item 4
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$150$150Dec 19, 1995Closed
Citation 2, item 1 Other-than-serious$0$0Dec 19, 1995Closed
Citation 2, item 2
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Dec 19, 1995Closed
Citation 2, item 3 Other-than-serious$0$0Dec 19, 1995Closed
Citation 2, item 4
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Dec 19, 1995Closed
Citation 2, item 5
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Dec 19, 1995Closed

Inspection 114777535 OPENED SEP 4, 1991Closed

Follow-up · Partial · Safety · 14 employees at the site · Closed Sep 24, 1991

540 Ajax Dr, Madison Heights, MI 48071 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 114783194 OPENED MAY 15, 1991Closed

Planned · Complete · Safety · 15 employees at the site · Closed Sep 24, 1991

540 Ajax Dr, Madison Heights, MI 48071 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$300$300Jun 6, 1991Closed
Citation 1, item 2 Serious$300$300Jun 6, 1991Closed
Citation 2, item 1 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 2 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 3 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 4 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 5 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 6 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 7 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 8 Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 9
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 10
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Jun 6, 1991Closed
Citation 2, item 11
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jun 6, 1991Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(i)

(2) General. (i) Containers in storage shall be located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.

29 CFR 1910.110(f)(2)(ii)

(ii) Containers when stored inside shall not be located near exits, stairways, or in areas normally used or intended for the safe exit of people.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 4080.1014

29 CFR 4081.11

29 CFR 4081.1115

29 CFR 4081.187

29 CFR 4081.213

29 CFR 4081.2131

29 CFR 4081.2154

29 CFR 4081.2161

29 CFR 4081.2193

29 CFR 4081.2620

29 CFR 4081.2622

29 CFR 4081.2635

29 CFR 4081.2648

29 CFR 4081.33

29 CFR 4081.3312

29 CFR 4081.34

29 CFR 4081.36

29 CFR 4081.4004

29 CFR 4081.4007

29 CFR 4081.4921

29 CFR 4081.4923

29 CFR 4081.711

29 CFR 4081.712

29 CFR 4081.716

29 CFR 4081.722

29 CFR 4081.727

29 CFR 4081.731

29 CFR 4081.736

Other machine shops employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.