Central Metal Fabricators, Inc.: OSHA inspections and violations

Miami, Florida · Fabricated Structural Metal Manufacturing · NAICS 332312

6inspections
26citation items
$6,324current penalties
Sep 21, 2018last inspection

OSHA has inspected Central Metal Fabricators, Inc. 6 times in Florida since 1987.

The latest one began on Sep 21, 2018 after a complaint, in Miami.

Those inspections ended with 26 citation items: 12 serious, 3 repeat and 11 other-than-serious.

Penalties were first proposed at $8,734 and now stand at $6,324, 28% lower after settlements or reviews.

Electrical wiring methods comes up most often in these citations: 5 items under 1910.305.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Central Metal Fabricators, Inc. averages $1,762 (2 cited inspections).

Central Metal Fabricators, Inc. also files yearly injury logs with OSHA, summarized below.

Central Metal Fabricators, Inc.: OSHA citation items per year, 1987 to 2018
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

319employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Central Metal Fabricators, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343479259 OPENED SEP 21, 2018Closed

Complaint · Partial · Safety · 22 employees at the site · Closed Mar 14, 2019

900 Sw 70th Ave, Miami, FL 33144 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,141$1,885Oct 11, 2018Final
Citation 2, item 1
29 CFR 1910.132(h)(6) · Personal protective equipment, general requirements
Other-than-serious$353$212Oct 11, 2018Final

Inspection 341419497 OPENED APR 22, 2016Closed

Planned · Partial · Health · 45 employees at the site · Closed Oct 28, 2016

900 Sw 70th Ave, Miami, FL 33144 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.253(b)(4)(i) · Gas welding and cutting
Serious$2,380$1,428Jul 29, 2016Final
Citation 2, item 1
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Other-than-serious$0$0Jul 29, 2016Final
Citation 2, item 2
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Other-than-serious$0$0Jul 29, 2016Final

Inspection 305504540 OPENED DEC 16, 2002Closed

Planned · Complete · Health · 45 employees at the site · Closed Dec 30, 2002

900 Sw 70 Ave., Miami, FL 33144 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 110054087 OPENED JUN 26, 1990Closed

Planned · Complete · Safety · 30 employees at the site · Closed Sep 4, 1990

900 Sw 70th Ave., Miami, FL 33144 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$150$150Jul 31, 1990Closed
Citation 1, item 1b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Jul 31, 1990Closed
Citation 1, item 1c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Jul 31, 1990Closed
Citation 1, item 2a
29 CFR 1910.252(a)(2)(iid) · Welding fire safety
Serious$150$150Jul 31, 1990Closed
Citation 1, item 2b
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Serious$0$0Jul 31, 1990Closed
Citation 1, item 3
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$150$150Jul 31, 1990Closed
Citation 1, item 4
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Serious$150$150Jul 31, 1990Closed
Citation 1, item 5
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$150$150Jul 31, 1990Closed
Citation 1, item 6
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$150$150Jul 31, 1990Closed
Citation 2, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Repeat$320$320Jul 31, 1990Closed
Citation 2, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Repeat$960$960Jul 31, 1990Closed
Citation 2, item 3
29 CFR 1910.305(b)(1) · Electrical wiring methods
Repeat$480$480Jul 31, 1990Closed
Citation 3, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Other-than-serious$0$0Jul 31, 1990Closed

Inspection 101206415 OPENED AUG 11, 1987Closed

Follow-up · Partial · Safety · 15 employees at the site · Closed Aug 14, 1987

900 Sw 70th Ave., Miami, FL 33144 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 101206233 OPENED JUN 16, 1987Closed

Planned · Complete · Safety · 33 employees at the site · Closed Nov 10, 1987

900 Sw 70th Ave., Miami, FL 33144 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$140$140Jun 29, 1987Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$60$0Jun 29, 1987Closed
Citation 2, item 2
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Other-than-serious$0$0Jun 29, 1987Closed
Citation 2, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Jun 29, 1987Closed
Citation 2, item 4
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Jun 29, 1987Closed
Citation 2, item 5
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jun 29, 1987Closed
Citation 2, item 6
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jun 29, 1987Closed
Citation 2, item 7
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0Jun 29, 1987Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Miami site logged 0 recordable injuries or illnesses among about 20 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Central Metal Fabricators, Inc.
Miami · 2023
20 000.03.6

Included with any plan: 6 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)

(h) Post-mortem data: Increased incidence and/or severity of post-mortem findings may be indicative of maternal toxicity. This can include gross or microscopic pathological findings or organ weight data, including absolute organ weight, organ-to-body weight ratio, or organ-to-brain weight ratio. When supported by findings of adverse histopathological effects in the affected organ(s), the observation of a significant change in the average weight of suspected target organ(s) of treated dams (mothers), compared to those in the control group, may be considered evidence of maternal toxicity.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other fabricated structural metal manufacturing employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.