OSHA SearchOSHA records by employer

Central Park Apartments: OSHA inspections and violations

Altamonte Springs, Florida · Lessors of Residential Buildings and Dwellings · NAICS 531110

1inspections
3citation items
$13,826current penalties
Sep 5, 2024last inspection

OSHA has inspected Central Park Apartments once in Florida.

The inspection began on Sep 5, 2024 after a complaint, in Altamonte Springs; the case is still open.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $13,826 and still stand at $13,826.

How that compares: the median penalty per cited inspection for real estate and rental employers since 2015 is $1,857, and Central Park Apartments averages $13,826 (1 cited inspection).

Central Park Apartments: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

321employers cited

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Central Park Apartments and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347734246 OPENED SEP 5, 2024Open

Complaint · Partial · Safety · 5 employees at the site · Open

525 One Center Boulevard, Altamonte Springs, FL 32701 · Lessors of Residential Buildings and Dwellings · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.36(d)(1) · Exit route design
Serious$6,913$6,913Oct 22, 2024Final
Citation 1, item 2
29 CFR 1910.37(a)(3) · Exit routes
Serious$6,913$6,913Oct 22, 2024Final
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Oct 22, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.36 · Exit route design

29 CFR 1910.36(d)(1)

(d) An exit door must be unlocked. (1) Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.

29 CFR 1910.37 · Exit routes

29 CFR 1910.37(a)(3)

(3) Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.