OSHA SearchOSHA records by employer

Cesar Ramirez Lozano: OSHA inspections and violations

Kernersville, North Carolina · Framing Contractors · NAICS 238130

1inspections
4citation items
$3,310current penalties
Jan 21, 2026last inspection

OSHA inspectors have visited Cesar Ramirez Lozano in North Carolina one time.

It opened on Jan 21, 2026 as a planned inspection, in Kernersville and is still open.

In all, OSHA issued 4 citation items: 2 serious and 2 other-than-serious.

The penalties, $3,310 in total, stand where OSHA first set them.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Cesar Ramirez Lozano averages $3,310 across 1 cited inspection.

Cesar Ramirez Lozano: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

230employers cited

48 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Cesar Ramirez Lozano and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348703372 OPENED JAN 21, 2026Open

Planned · Complete · Safety · 3 employees at the site · Open

954 Riverbank Drive, Lot 008, Kernersville, NC 27284 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,310$3,310Feb 27, 2026Final
Citation 1, item 1b
29 CFR 1926.503(b)(1) · Fall protection training in construction
Serious$0$0Feb 27, 2026Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(viii) · Fire protection
Other-than-serious$0$0Feb 27, 2026Final
Citation 2, item 2
29 CFR 1926.306(b)(3)(i) · Air receivers
Other-than-serious$0$0Feb 27, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(viii)

(viii) Portable fire extinguishers shall be inspected periodically and maintained in accordance with Maintenance and Use of Portable Fire Extinguishers, NFPA No. 10A-1970.

29 CFR 1926.306 · Air receivers

29 CFR 1926.306(b)(3)(i)

(3) Gages and valves. (i) Every air receiver shall be equipped with an indicating pressure gage (so located as to be readily visible) and with one or more spring-loaded safety valves. The total relieving capacity of such safety valves shall be such as to prevent pressure in the receiver from exceeding the maximum allowable working pressure of the receiver by more than 10 percent.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.