OSHA SearchOSHA records by employer

CFV Solar Testing Lab: OSHA inspections and violations

Albuquerque, New Mexico · Testing Laboratories and Services · NAICS 541380

1inspections
2citation items
$3,000current penalties
Mar 22, 2016last inspection

OSHA has inspected CFV Solar Testing Lab once in New Mexico.

The inspection began on Mar 22, 2016 on a referral, in Albuquerque.

That inspection ended with 2 citation items: 2 serious.

Penalties were first proposed at $3,000 and still stand at $3,000.

Woodworking machinery comes up most often in these citations: 2 items under 1910.213.

How that compares: the median penalty per cited inspection for professional services employers since 2015 is $1,821, and CFV Solar Testing Lab averages $3,000 (1 cited inspection).

CFV Solar Testing Lab: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites CFV Solar Testing Lab again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341388262 OPENED MAR 22, 2016Closed

Referral · Partial · Health · 7 employees at the site · Closed May 16, 2016

5600 University Blvd. Se, Albuquerque, NM 87106 · Testing Laboratories and Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,500$1,500Apr 18, 2016Final
Citation 1, item 2
29 CFR 1910.213(s)(9) · Woodworking machinery
Serious$1,500$1,500Apr 18, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(s)(9)

(9) Push sticks or push blocks shall be provided at the work place in the several sizes and types suitable for the work to be done.