OSHA SearchOSHA records by employer

CGD Construction LLC: OSHA inspections and violations

Duncan, South Carolina · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
4citation items
$8,600current penalties
Oct 24, 2022last inspection

OSHA has inspected CGD Construction LLC once in South Carolina.

The inspection began on Oct 24, 2022 on a referral, in Duncan.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $8,600 and still stand at $8,600.

Excavations comes up most often in these citations: 2 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and CGD Construction LLC averages $8,600 (1 cited inspection).

CGD Construction LLC: OSHA citation items per year, 2022 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites CGD Construction LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346316557 OPENED OCT 24, 2022Closed

Referral · Partial · Safety · 4 employees at the site · Closed Apr 7, 2026

150 E. Main Street, Duncan, SC 29334 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$1,500$1,500Mar 30, 2023Final
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$1,500$1,500Mar 30, 2023Final
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$2,800$2,800Mar 30, 2023Final
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,800$2,800Mar 30, 2023Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in South Carolina

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.