OSHA SearchOSHA records by employer

CGS Electric LLC: OSHA inspections and violations

Washington, District of Columbia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
4citation items
$3,500current penalties
Aug 15, 2025last inspection

CGS Electric LLC has one OSHA inspection on record in District of Columbia.

OSHA opened it on Aug 15, 2025 as a planned inspection, in Washington, and the case has not closed yet.

From that inspection OSHA issued 4 citation items: 4 serious.

OSHA proposed $4,965 in penalties. After settlements and reviews the total is $3,500, down 30%.

Most often, OSHA cited 1926.651, excavations (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. CGS Electric LLC averages $3,500 over 1 cited inspection in that time.

CGS Electric LLC: OSHA citation items per year, 2025 to 2025
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

13employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch CGS Electric LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348441064 OPENED AUG 15, 2025Open

Planned · Partial · Safety · 5 employees at the site · Open

3900 Georgia Ave, Washington, DC 20011 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(c)(2) · Excavations
Serious$4,965$3,500Jan 16, 2026Final
Citation 1, item 1b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Jan 16, 2026Final
Citation 1, item 1c
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jan 16, 2026Final
Citation 1, item 1d
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jan 16, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other electrical contractors and other wiring installation contractors employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.