OSHA SearchOSHA records by employer

Chacon Drywall, LLC: OSHA inspections and violations

West Chester, Ohio · Drywall and Insulation Contractors · NAICS 238310

1inspections
2citation items
$19,116current penalties
Dec 12, 2024last inspection

OSHA inspectors have visited Chacon Drywall, LLC in Ohio one time.

It opened on Dec 12, 2024 on a referral, in West Chester.

In all, OSHA issued 2 citation items: 1 serious and 1 repeat.

The proposed penalties came to $38,231; today they stand at $19,116, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Chacon Drywall, LLC averages $19,116 across 1 cited inspection.

Chacon Drywall, LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

273employers cited

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Chacon Drywall, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347933707 OPENED DEC 12, 2024Closed

Referral · Partial · Safety · 10 employees at the site · Closed Mar 30, 2026

7950 Union Center Boulevard, West Chester, OH 45011 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$12,744$6,372Mar 18, 2025Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$25,487$12,744Mar 18, 2025Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(g)(1)(vii)

(vii) For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(1)

(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.

Other drywall and insulation contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.