OSHA SearchOSHA records by employer

Chads Construction Services Inc.: OSHA inspections and violations

Macedon, New York · Roofing Contractors · NAICS 238160

1inspections
3citation items
$2,668current penalties
Feb 5, 2026last inspection

OSHA has inspected Chads Construction Services Inc. once in New York.

The inspection began on Feb 5, 2026 as a planned inspection, in Macedon; the case is still open.

That inspection ended with 3 citation items: 2 serious and 1 other-than-serious.

Penalties were first proposed at $2,668 and still stand at $2,668.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Chads Construction Services Inc. averages $2,668 (1 cited inspection).

Chads Construction Services Inc.: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

57 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Chads Construction Services Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348727702 OPENED FEB 5, 2026Open

Planned · Partial · Safety · 4 employees at the site · Open

Lot 21, Oakridge Lane, Macedon, NY 14502 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,270$2,270Mar 26, 2026Final
Citation 1, item 1b
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$0$0Mar 26, 2026Final
Citation 2, item 1
29 CFR 1903.19(c)(1) · Proving cited hazards were fixed
Other-than-serious$398$398May 28, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(c)(1)

(c) Abatement certification. (1) Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(13)

(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.503(c)(3)

(3) Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill.

Other roofing contractors employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.