OSHA SearchOSHA records by employer

Chamness Technology, Inc: OSHA inspections and violations

Dodge City, Kansas · Materials Recovery Facilities · NAICS 562920

1inspections
3citation items
$3,109current penalties
Dec 21, 2016last inspection

OSHA inspectors have visited Chamness Technology, Inc in Kansas one time.

It opened on Dec 21, 2016 after a complaint, in Dodge City.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $4,441; today they stand at $3,109, 30% less.

The rule cited most here is 1910.253 (gas welding and cutting), 2 times.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,201 penalty. Chamness Technology, Inc averages $3,109 across 1 cited inspection.

Chamness Technology, Inc: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Chamness Technology, Inc again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341988772 OPENED DEC 21, 2016Closed

Complaint · Partial · Safety · 11 employees at the site · Closed Jan 31, 2017

10972 Denim Rd, Dodge City, KS 67801 · Materials Recovery Facilities · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.253(b)(2)(ii) · Gas welding and cutting
Serious$3,741$2,619Jan 5, 2017Final
Citation 1, item 1b
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$0$0Jan 5, 2017Final
Citation 2, item 1
29 CFR 1904.30(a) · Multiple business establishments
Other-than-serious$700$490Jan 5, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.30 · Multiple business establishments

29 CFR 1904.30(a)

(a) Basic requirement. You must keep a separate OSHA 300 Log for each establishment that is expected to be in operation for one year or longer.

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.253(b)(2)(ii)

(ii) Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.

29 CFR 1910.253(b)(4)(iii)

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.

Other materials recovery facilities employers in Kansas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.