OSHA SearchOSHA records by employer

Champion Maintenance Contractors, Inc.: OSHA inspections and violations

Derby, Connecticut · Water and Sewer Line and Related Structures Construction · NAICS 237110

1inspections
7citation items
$11,000current penalties
Feb 24, 2017last inspection

Champion Maintenance Contractors, Inc. has one OSHA inspection on record in Connecticut.

OSHA opened it on Feb 24, 2017 on a referral, in Derby.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $16,841 in penalties. After settlements and reviews the total is $11,000, down 35%.

Most often, OSHA cited 1926.651, excavations (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Champion Maintenance Contractors, Inc. averages $11,000 over 1 cited inspection in that time.

Champion Maintenance Contractors, Inc.: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Connecticut · latest 90 days of OSHA records

89employers cited

Get notified the morning OSHA posts each new citation in Connecticut: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Connecticut

Checking a subcontractor, a client or your own company? Watch Champion Maintenance Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342132149 OPENED FEB 24, 2017Closed

Referral · Partial · Safety · 3 employees at the site · Closed Jan 27, 2023

656 New Haven Avenue, Derby, CT 06418 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$2,716$1,750Jul 19, 2017Final
Citation 1, item 2a
29 CFR 1926.652(a)(1) · Trench protection
Serious$3,803$2,500Jul 19, 2017Final
Citation 1, item 2b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Jul 19, 2017Final
Citation 1, item 3
29 CFR 1926.651(h)(1) · Excavations
Serious$3,803$2,500Jul 19, 2017Final
Citation 1, item 4
29 CFR 1926.651(i)(3) · Excavations
Serious$3,803$2,500Jul 19, 2017Final
Citation 1, item 5a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,716$1,750Jul 19, 2017Final
Citation 1, item 5b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Jul 19, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in Connecticut

Alert subscribers get notified of each newly cited employer in Connecticut the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.