OSHA SearchOSHA records by employer

Champion Painting, Inc.: OSHA inspections and violations

Bozeman, Montana · Painting and Wall Covering Contractors · NAICS 238320

1inspections
6citation items
$4,169current penalties
Jun 30, 2016last inspection

OSHA has inspected Champion Painting, Inc. once in Montana.

The inspection began on Jun 30, 2016 as part of a related case, in Bozeman.

That inspection ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $6,948 and now stand at $4,169, 40% lower after settlements or reviews.

Flammable liquids comes up most often in these citations: 4 items under 1910.106.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Champion Painting, Inc. averages $4,169 (1 cited inspection).

Champion Painting, Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Montana · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in Montana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Montana

Checking a subcontractor, a client or your own company? Watch Champion Painting, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341596476 OPENED JUN 30, 2016Closed

Unprogrammed related · Partial · Health · 5 employees at the site · Closed Dec 2, 2016

251 Evergreen Drive, Bozeman, MT 59715 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$2,672$1,603Nov 15, 2016Final
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Nov 15, 2016Final
Citation 1, item 1c
29 CFR 1910.106(d)(5)(vi)(a) · Flammable liquids
Serious$0$0Nov 15, 2016Final
Citation 1, item 2
29 CFR 1910.106(d)(5)(iii) · Flammable liquids
Serious$2,672$1,603Nov 15, 2016Final
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,604$962Nov 15, 2016Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Nov 15, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(d)(5)(iii)

(iii) Office occupancies. Storage shall be prohibited except that which is required for maintenance and operation of building and operation of equipment. Such storage shall be kept in closed metal containers stored in a storage cabinet or in safety cans or in an inside storage room not having a door that opens into that portion of the building used by the public.