OSHA SearchOSHA records by employer

Charles Kirchner and Sons Inc.: OSHA inspections and violations

Princeton, Indiana · Other Building Material Dealers · NAICS 444190

1inspections
6citation items
$228current penalties
Apr 9, 2024last inspection

OSHA has inspected Charles Kirchner and Sons Inc. once in Indiana.

The inspection began on Apr 9, 2024 after a complaint, in Princeton.

That inspection ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $350 and now stand at $228, 35% lower after settlements or reviews.

Woodworking machinery comes up most often in these citations: 3 items under 1910.213.

How that compares: the median penalty per cited inspection for retail employers since 2015 is $1,750, and Charles Kirchner and Sons Inc. averages $228 (1 cited inspection).

Charles Kirchner and Sons Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Charles Kirchner and Sons Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347400806 OPENED APR 9, 2024Closed

Complaint · Complete · Safety · 6 employees at the site · Closed Jul 3, 2024

2001 East Broadway Street, Princeton, IN 47670 · Other Building Material Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$200$130Jun 3, 2024Final
Citation 1, item 1b
29 CFR 1910.213(c)(2) · Woodworking machinery
Serious$0$0Jun 3, 2024Final
Citation 1, item 1c
29 CFR 1910.213(c)(3) · Woodworking machinery
Serious$0$0Jun 3, 2024Final
Citation 1, item 2a
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$100$65Jun 3, 2024Final
Citation 1, item 2b
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$0$0Jun 3, 2024Final
Citation 2, item 1
29 CFR 1910.141(a)(5) · Sanitation
Other-than-serious$50$32Jun 3, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.141 · Sanitation

29 CFR 1910.141(a)(5)

(5) Vermin control. Every enclosed workplace shall be so constructed, equipped, and maintained, so far as reasonably practicable, as to prevent the entrance or harborage of rodents, insects, and other vermin. A continuing and effective extermination program shall be instituted where their presence is detected.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.213(c)(1)

(c) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1910.213(c)(2)

(2) Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced.

29 CFR 1910.305 · Electrical wiring methods