OSHA SearchOSHA records by employer

Chava Gonzalez Masonry: OSHA inspections and violations

Mason, Ohio · Masonry Contractors · NAICS 238140

1inspections
7citation items
$38,286current penalties
Feb 28, 2018last inspection

OSHA has inspected Chava Gonzalez Masonry once in Ohio.

The inspection began on Feb 28, 2018 as a planned inspection, in Mason.

That inspection ended with 7 citation items: 5 serious and 2 repeat.

Penalties were first proposed at $95,716 and now stand at $38,286, 60% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Chava Gonzalez Masonry averages $38,286 (1 cited inspection).

Chava Gonzalez Masonry: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Ohio · latest 90 days of OSHA records

260employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Ohio: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Ohio

Checking a subcontractor, a client or your own company? Watch Chava Gonzalez Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342981818 OPENED FEB 28, 2018Closed

Planned · Partial · Safety · 7 employees at the site · Closed Mar 25, 2022

3467 Hudson Hills Ln, Mason, OH 45040 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$12,934$5,174Apr 10, 2018Final
Citation 1, item 1b
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$0$0Apr 10, 2018Final
Citation 1, item 2a
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$12,934$5,174Apr 10, 2018Final
Citation 1, item 2b
29 CFR 1926.451(g)(4)(xv) · Scaffolds, general requirements
Serious$0$0Apr 10, 2018Final
Citation 1, item 3
29 CFR 1926.454(a) · Scaffold training
Serious$12,934$5,174Apr 10, 2018Final
Citation 2, item 1
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Repeat$28,457$11,383Apr 10, 2018Final
Citation 2, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$28,457$11,383Apr 10, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(b)(4)

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm).

29 CFR 1926.451(f)(7)

(7) Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in Ohio

Alert subscribers get notified of each newly cited employer in Ohio the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.