OSHA SearchOSHA records by employer

Chicago Bricks Development Group, LLC: OSHA inspections and violations

Chicago, Illinois · Residential Remodelers · NAICS 236118

1inspections
5citation items
$3,694current penalties
Mar 19, 2019last inspection

OSHA inspectors have visited Chicago Bricks Development Group, LLC in Illinois one time.

It opened on Mar 19, 2019, in Chicago.

In all, OSHA issued 5 citation items: 5 serious.

The proposed penalties came to $7,388; today they stand at $3,694, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Chicago Bricks Development Group, LLC averages $3,694 across 1 cited inspection.

Chicago Bricks Development Group, LLC: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

413employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Chicago Bricks Development Group, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343862397 OPENED MAR 19, 2019Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Jan 22, 2020

3632 N. Magnolia Ave., Chicago, IL 60613 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$2,842$1,421Sep 3, 2019Final
Citation 1, item 1b
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$0$0Sep 3, 2019Final
Citation 1, item 1c
29 CFR 1926.405(b)(2) · Job-site wiring
Serious$0$0Sep 3, 2019Final
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,273$1,136Sep 3, 2019Final
Citation 1, item 3
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$2,273$1,136Sep 3, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(c)(1)(ii)

(ii) One stairrail system along each unprotected side or edge.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

Other residential remodelers employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.