OSHA SearchOSHA records by employer

Chris Villarreal: OSHA inspections and violations

Corpus Christi, Texas · Masonry Contractors · NAICS 238140

3inspections
8citation items
$8,928current penalties
Oct 29, 2019last inspection

Since 2010, OSHA inspectors have visited Chris Villarreal in Texas 3 times.

The most recent inspection opened on Oct 29, 2019 as part of a related case, in Corpus Christi.

In all, OSHA issued 8 citation items: 8 serious.

The penalties, $8,928 in total, stand where OSHA first set them.

The rule cited most here is 1926.451 (scaffolds, general requirements), 6 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Chris Villarreal averages $3,978 across 1 cited inspection.

Chris Villarreal: OSHA citation items per year, 2010 to 2019
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

13 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Chris Villarreal and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344412549 OPENED OCT 29, 2019Closed

Unprogrammed related · Partial · Safety · 4 employees at the site · Closed Dec 20, 2023

7001 Lipes Boulevard, Corpus Christi, TX 78414 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$3,978$3,978Dec 5, 2019Final
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Dec 5, 2019Final
Citation 1, item 1c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Dec 5, 2019Final
Citation 1, item 1d
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Dec 5, 2019Final

Inspection 315098681 OPENED NOV 2, 2010Closed

Planned · Partial · Safety · 3 employees at the site · Closed Dec 15, 2015

7714 Fred's Folly Dr, Corpus Christi, TX 78414 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(b) · Hard hats in construction
Serious$3,000$3,000Feb 22, 2011Closed

Inspection 314197708 OPENED MAR 23, 2010Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 10, 2014

7513 Rancho Vista, Corpus Christi, TX 78414 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$750$750May 17, 2010Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$450$450May 17, 2010Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$750$750May 17, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.452 · Rules for each type of scaffold

Other masonry contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.