Inspection 348633991 OPENED DEC 10, 2025Closed
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Cinnaminson, New Jersey · Sewage Treatment Facilities · NAICS 221320
Cinnaminson Sewerage Authority has 14 OSHA inspections on record in New Jersey, the first in 2004.
OSHA's last visit started on Dec 10, 2025 to monitor an earlier case, in Cinnaminson.
Across those inspections OSHA issued 49 citation items: 41 serious and 8 other-than-serious.
OSHA proposed $50,950 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.147, lockout/tagout (5 items).
For context, across all utility employers the median penalty per cited inspection since 2015 is $0. Cinnaminson Sewerage Authority averages $10,190 over 5 cited inspections in that time.
New Jersey · latest 90 days of OSHA records
274employers cited
7 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Cinnaminson Sewerage Authority and get notified the morning OSHA posts a new citation for it.
Watch this company400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response |
Serious | $2,800 | $2,800 | Oct 3, 2025 | Final |
| Citation 1, item 2 29 CFR 1910.120(q)(6)(ii) · Hazardous waste operations and emergency response |
Serious | $2,800 | $2,800 | Oct 3, 2025 | Final |
| Citation 1, item 3 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Serious | $2,800 | $2,800 | Oct 3, 2025 | Final |
| Citation 1, item 4 29 CFR 1910.134(e)(6)(i) · Respiratory protection |
Serious | $2,800 | $2,800 | Oct 3, 2025 | Final |
| Citation 1, item 5 29 CFR 1910.1030(h)(1)(ii)(b) · Bloodborne pathogens |
Serious | $2,400 | $2,400 | Oct 3, 2025 | Final |
| Citation 1, item 6 29 CFR 1910.1450(e)(1) · Occupational exposure to hazardous chemicals in laboratories |
Serious | $2,800 | $2,800 | Oct 3, 2025 | Final |
| Citation 2, item 1 29 CFR 1910.141(a)(3)(i) · Sanitation |
Other-than-serious | $400 | $400 | Oct 3, 2025 | Final |
| Citation 2, item 2 29 CFR N.J.A.C. 12:100-13.4(C) |
Other-than-serious | $400 | $400 | Oct 3, 2025 | Final |
Central Pump Station Riverton Road, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Fairfax Pump Station 142 Fairfax Road, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $2,800 | $2,800 | Oct 3, 2025 | Final |
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(b)(6) · Exit routes |
Serious | $2,800 | $2,800 | Aug 19, 2025 | Final |
| Citation 1, item 2 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $750 | $750 | Aug 19, 2025 | Final |
| Citation 1, item 3 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $750 | $750 | Aug 19, 2025 | Final |
| Citation 1, item 4 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $2,800 | $2,800 | Aug 19, 2025 | Final |
| Citation 1, item 5 29 CFR 1910.303(h)(5)(iii)(b) · Electrical equipment, general requirements |
Serious | $750 | $750 | Aug 19, 2025 | Final |
| Citation 1, item 6 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $750 | $750 | Aug 19, 2025 | Final |
| Citation 1, item 7 29 CFR N.J.S.A. 34:6A-33(A) |
Serious | $750 | $750 | Aug 19, 2025 | Final |
| Citation 1, item 8 29 CFR N.J.S.A. 34:6A-33(A) |
Serious | $2,800 | $2,800 | Aug 19, 2025 | Final |
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $2,000 | $2,000 | Aug 29, 2017 | Final |
| Citation 2, item 1 29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements |
Other-than-serious | $400 | $400 | Aug 29, 2017 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $400 | $400 | Aug 29, 2017 | Final |
| Citation 2, item 3 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Other-than-serious | $400 | $400 | Aug 29, 2017 | Final |
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
400 North Randolph Ave, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Serious | $1,600 | $1,600 | Feb 24, 2015 | Final |
| Citation 1, item 2 29 CFR 1910.146(c)(2) · Permit-required confined spaces |
Serious | $2,000 | $2,000 | Feb 24, 2015 | Final |
| Citation 1, item 3 29 CFR 1910.146(k)(1)(i) · Permit-required confined spaces |
Serious | $2,000 | $2,000 | Feb 24, 2015 | Final |
| Citation 1, item 4 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $1,600 | $1,600 | Feb 24, 2015 | Final |
| Citation 1, item 5 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $1,600 | $1,600 | Feb 24, 2015 | Final |
| Citation 1, item 6 29 CFR 1910.212(b) · Machine guarding |
Serious | $1,600 | $1,600 | Feb 24, 2015 | Final |
| Citation 1, item 7 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $2,000 | $2,000 | Feb 24, 2015 | Final |
| Citation 1, item 8 29 CFR 1926.601(b)(4) · Motor vehicles |
Serious | $2,000 | $2,000 | Feb 24, 2015 | Final |
| Citation 2, item 1 29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags |
Other-than-serious | $400 | $400 | Feb 24, 2015 | Final |
| Citation 2, item 2 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $400 | $400 | Feb 24, 2015 | Final |
| Citation 2, item 3 29 CFR 1910.157(g)(2) · Portable fire extinguishers |
Other-than-serious | $400 | $400 | Feb 24, 2015 | Final |
400 North Randolph Street, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
400 North Randolph Street, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a)(3) · Exit routes |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 2 29 CFR 1910.145(c)(3) · Specifications for accident prevention signs and tags |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 3 29 CFR 1910.146(k)(1)(iii) · Permit-required confined spaces |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 4 29 CFR 1910.181(j)(2)(ii) · Derricks |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 5 29 CFR 1910.215(a)(1) · Grinders and abrasive wheels |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 6 29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 7 29 CFR 1910.304(f)(2) · Grounding and circuit protection |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 8 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
| Citation 1, item 9 29 CFR 6A0033 A |
Serious | $0 | $0 | Apr 20, 2006 | Closed |
Pumping Stations, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Pumping Stations, Cinnaminson, NJ 08077 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.22(b)(1) · General requirements |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
| Citation 1, item 2 29 CFR 1910.22(c) · General requirements |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
| Citation 1, item 3 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
| Citation 1, item 4 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
| Citation 1, item 5 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
| Citation 1, item 6 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
| Citation 1, item 7 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
| Citation 1, item 8 29 CFR 1910.305(j)(1)(iv) · Electrical wiring methods |
Serious | $0 | $0 | Jun 8, 2004 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.120(q)(1)
(1) A laminated, dated card or certificate with photo, denoting limitations and level of protection for which the employee is trained should be issued to those students successfully completing a course.
29 CFR 1910.120(q)(6)(ii)
(ii) First responder operations level. First responders at the operations level are individuals who respond to releases or potential releases of hazardous substances as part of the initial response to the site for the purpose of protecting nearby persons, property, or the environment from the effects of the release. They are trained to respond in a defensive fashion without actually trying to stop the release. Their function is to contain the release from a safe distance, keep it from spreading, and prevent exposures. First responders at the operational level shall have received at least eight hours of training or have had sufficient experience to objectively demonstrate competency in the following areas in addition to those listed for the awareness level and the employer shall so certify:
29 CFR 1910.132(d)(1)
(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.