OSHA SearchOSHA records by employer

Circle K Stores Inc: OSHA inspections and violations

Albany, Oregon · Convenience Stores · NAICS 445120

14inspections
17citation items
$3,605current penalties
Jan 19, 2024last inspection

Circle K Stores Inc has 14 OSHA inspections on record in Oregon, the first in 1993.

OSHA's last visit started on Jan 19, 2024 after a complaint, in Newberg.

Across those inspections OSHA issued 17 citation items: 4 serious and 13 other-than-serious.

OSHA proposed $3,605 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Circle K Stores Inc averages $850 over 3 cited inspections in that time.

Circle K Stores Inc: OSHA citation items per year, 1993 to 2024
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

383employers cited

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Circle K Stores Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Company-wide record

OSHA records show Circle K Stores Inc at 46 sites in 10 states. Together they've had 60 inspections and $383,846 in current penalties.

We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.

Included with any plan: the site-by-site record for all 46 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.

See plans

Inspection history

Inspection 347220873 OPENED JAN 19, 2024Closed

Complaint · Partial · Safety · 13 employees at the site · Closed May 20, 2024

1500 E Portland Rd, Newberg, OR 97132 · Convenience Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0765(1)-2
Other-than-serious$0$0Mar 1, 2024Final

Inspection 346240781 OPENED AUG 15, 2022Closed

Complaint · Partial · Health · 24 employees at the site · Closed Apr 25, 2023

22 N Coast Hwy, Newport, OR 97365 · Gasoline Stations with Convenience Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR OAR 437-001-0765(1)-2
Other-than-serious$100$100Nov 21, 2022Final

Inspection 343254314 OPENED JUN 20, 2018Open

Planned · Complete · Safety · 9 employees at the site · Open

333 34th Ave Se, Albany, OR 97322 · Convenience Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$2,450$2,450Oct 12, 2018Final

Inspection 315423079 OPENED APR 7, 2011Closed

Complaint · Partial · Health · 16 employees at the site · Closed Jul 12, 2011

12230 Se Sunnyside Rd, Clackamas, OR 97015 · Convenience Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$105$105Apr 22, 2011Closed

Inspection 313679284 OPENED DEC 22, 2009Closed

Planned · Complete · Safety · 9 employees at the site · Closed Apr 30, 2010

200 Ne Santiam Blvd, Mill City, OR 97360 · Convenience Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jan 11, 2010Closed
Citation 1, item 2
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Other-than-serious$0$0Jan 11, 2010Closed
Citation 1, item 3 Other-than-serious$0$0Jan 11, 2010Closed

Inspection 306974353 OPENED JUN 17, 2004Closed

Complaint · Partial · Health · 12 employees at the site · Closed Jun 17, 2004

3520 Gateway, Springfield, OR 97477 · Convenience Stores · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307324483 OPENED FEB 25, 2004Closed

Planned · No inspection · Safety · Closed Feb 25, 2004

836 Ne A St, Grants Pass, OR 97526 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306469552 OPENED JAN 13, 2004Closed

Planned · No inspection · Safety · Closed Jan 13, 2004

3109 Portland Rd, Newberg, OR 97132 · Oil and Gas Extraction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

6 older inspections

Inspection 303177869 OPENED AUG 31, 2000Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Feb 9, 2001

333 34th Ave Se, Albany, OR 97321 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(1) · General requirements
Other-than-serious$0$0Sep 29, 2000Closed

Inspection 300914892 OPENED JUL 1, 1998Closed

Complaint · Complete · Safety · 9 employees at the site · Closed Jul 21, 1999

300 Queens Ave S, Albany, OR 97321 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Jul 20, 1998Closed

Inspection 302140413 OPENED MAY 7, 1998Closed

Planned · No inspection · Safety · Closed May 7, 1998

20525 Ne Wistfull Vista, Troutedale, OR 97060 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 124683665 OPENED JAN 17, 1996Closed

Follow-up · Complete · Safety · 6 employees at the site · Closed Jan 17, 1996

2405 Hwy 20, Sweet Home, OR 97386 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126705235 OPENED OCT 16, 1995Closed

Planned · Complete · Safety · 6 employees at the site · Closed Apr 23, 1996

2405 Hwy 20, Sweet Home, OR 97386 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(k)(2) · Exit routes
Serious$300$300Nov 15, 1995Final
Citation 2, item 2
29 CFR 1910.101(b) · Compressed gases (general requirements)
Other-than-serious$0$0Nov 15, 1995Closed
Citation 2, item 3 Other-than-serious$0$0Nov 15, 1995Closed
Citation 2, item 4
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Nov 15, 1995Closed
Citation 2, item 5
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Nov 15, 1995Closed
Citation 2, item 6 Other-than-serious$500$500Nov 15, 1995Final

Inspection 123737595 OPENED APR 8, 1993Closed

Planned · Complete · Safety · 5 employees at the site · Closed Apr 18, 1994

836 Ne A St, Grants Pass, OR 97526 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$150$150Apr 28, 1993Closed
Citation 2, item 2
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Apr 28, 1993Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(e)(3)

(3) The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 7010.7650

29 CFR 7020.1440

29 CFR 7020.1610

29 CFR 7020.410

29 CFR 7630.100

Other convenience stores employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.