OSHA SearchOSHA records by employer

Citadel Construction Inc: OSHA inspections and violations

Bend, Oregon · Commercial and Institutional Building Construction · NAICS 236220

5inspections
10citation items
$2,225current penalties
Mar 7, 2016last inspection

Citadel Construction Inc has 5 OSHA inspections on record in Oregon, the first in 1989.

OSHA's last visit started on Mar 7, 2016 as a planned inspection, in Coos Bay.

Across those inspections OSHA issued 10 citation items: 7 serious and 3 other-than-serious.

OSHA proposed $2,340 in penalties. After settlements and reviews the total is $2,225, down 5%.

Most often, OSHA cited 1926.453, aerial lifts (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Citadel Construction Inc averages $1,960 over 1 cited inspection in that time.

Citadel Construction Inc: OSHA citation items per year, 1989 to 2016
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

383employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Citadel Construction Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341307106 OPENED MAR 7, 2016Closed

Planned · Partial · Safety · 2 employees at the site · Closed Dec 8, 2016

925 S Broadway, Coos Bay, OR 97420 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$200$200Aug 5, 2016Final
Citation 1, item 2
29 CFR 1926.403(b)(1)(ii) · Electrical equipment on job sites
Serious$120$120Aug 5, 2016Final
Citation 1, item 3 Serious$120$120Aug 5, 2016Final
Citation 1, item 4
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$120$120Aug 5, 2016Final
Citation 1, item 5
29 CFR OAR 437-003-1501
Serious$1,400$1,400Aug 5, 2016Final

Inspection 311204259 OPENED OCT 26, 2007Closed

Planned · Complete · Safety · 15 employees at the site · Closed Oct 26, 2007

300 Nw Quince Ave, Redmond, OR 97756 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301291670 OPENED FEB 23, 1999Closed

Planned · Complete · Safety · 2 employees at the site · Closed Mar 15, 1999

Grand Auto Store/warehouse Hwy 11 And Main Street, Milton-freewater, OR 97862 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105349229 OPENED MAY 23, 1989Closed

Planned · Complete · Safety · 5 employees at the site · Closed May 7, 1993

60 Ne Bend River Mall Blvd, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$75$50Jun 20, 1989Final
Citation 1, item 2
29 CFR 1926.450(a)(2) · Scope, application and definitions applicable to this subpart
Serious$105$65Jun 20, 1989Final
Citation 2, item 3
29 CFR 7030020 A
Other-than-serious$200$150Jun 20, 1989Final

Inspection 105349062 OPENED APR 27, 1989Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jul 6, 1989

60 Ne Bend River Mall Blvd, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0May 12, 1989Closed
Citation 1, item 2 Other-than-serious$0$0May 12, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(1)(ii)

(ii) Mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided.

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.450(a)(2)

(a) Scope and application. This subpart applies to all scaffolds used in workplaces covered by this part. It does not apply to crane or derrick suspended personnel platforms. The criteria for aerial lifts are set out exclusively in § 1926.453.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 7127.15

29 CFR 7155.15

Other commercial and institutional building construction employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.