OSHA SearchOSHA records by employer

City of Barre: OSHA inspections and violations

Barre, Vermont · Site Preparation Contractors · NAICS 238910

11inspections
77citation items
$24,050current penalties
Jun 8, 2016last inspection

Since 1985, OSHA inspectors have visited City of Barre in Vermont 11 times.

The most recent inspection opened on Jun 8, 2016 on a referral, in Barre.

In all, OSHA issued 77 citation items: 33 serious and 44 other-than-serious.

The proposed penalties came to $52,945; today they stand at $24,050, 55% less.

The rule cited most here is 1910.305 (electrical wiring methods), 10 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. City of Barre averages $1,000 across 1 cited inspection.

City of Barre: OSHA citation items per year, 1985 to 2016
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

29employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch City of Barre and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341534170 OPENED JUN 8, 2016Closed

Referral · Partial · Safety · Local government · 100 employees at the site · Closed Jul 28, 2016

Summer Street, Barre, VT 05641 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.200(g)(1) · Accident prevention signs and tags
Serious$2,100$1,000Jun 21, 2016Final

Inspection 314221524 OPENED APR 10, 2012Closed

Referral · Partial · Safety · Local government · 12 employees at the site · Closed Apr 10, 2012

Main St, Barre, VT 05641 · Executive Offices · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314221532 OPENED APR 10, 2012Closed

Unprogrammed related · No inspection · Safety · Local government · 150 employees at the site · Closed Jun 29, 2012

Main St, Barre, VT 05641 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311482020 OPENED JUL 14, 2009Closed

Referral · Partial · Safety · Local government · 21 employees at the site · Closed Aug 24, 2009

Academy & Mount Streest, Barre, VT 05641 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(c)(2)(iii) · Trench protection
Other-than-serious$0$0Jul 30, 2009Closed

Inspection 311476469 OPENED MAR 18, 2008Closed

Planned · Complete · Safety · Local government · 21 employees at the site · Closed Sep 10, 2009

Prospect St At Bridge, Barre, VT 05641 · Site Preparation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$600$600Jul 31, 2008Final
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Other-than-serious$600$600Jul 31, 2008Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Other-than-serious$28,000$11,500Jul 31, 2008Final

Inspection 305535528 OPENED APR 14, 2004Closed

Planned · Complete · Safety · Local government · 60 employees at the site · Closed Dec 20, 2004

6 North Main Street, Barre, VT 05641 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.25(d)(1)(x) · Portable wood ladders
Serious$900$450Sep 21, 2004Closed
Citation 1, item 2
29 CFR 1910.110(f)(2)(ii) · Storage and handling of liquefied petroleum gases
Serious$675$300Sep 21, 2004Closed
Citation 1, item 3
29 CFR 1910.212(b) · Machine guarding
Serious$675$300Sep 21, 2004Closed
Citation 1, item 4a
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$675$300Sep 21, 2004Closed
Citation 1, item 4b
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$0$0Sep 21, 2004Closed
Citation 1, item 4c
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Sep 21, 2004Closed
Citation 1, item 5
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Serious$900$450Sep 21, 2004Closed
Citation 2, item 1
29 CFR 1910.151(b) · First aid and eyewash
Other-than-serious$0$0Sep 21, 2004Closed
Citation 2, item 2
29 CFR 1910.244(a)(1)(ii) · Other portable tools and equipment
Other-than-serious$0$0Sep 21, 2004Closed

Inspection 303457063 OPENED MAY 28, 2002Closed

Unprogrammed other · Partial · Safety · Local government · 95 employees at the site · Closed Sep 13, 2002

590 North Main Street, Barre, VT 05641 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$2,500$1,500Jul 29, 2002Closed
Citation 1, item 2
29 CFR 1926.651(h)(1) · Excavations
Other-than-serious$2,500$0Jul 29, 2002Closed
Citation 1, item 3
29 CFR 1926.651(j)(2) · Excavations
Serious$2,500$1,750Jul 29, 2002Closed
Citation 1, item 4
29 CFR 1926.651(k)(1) · Excavations
Serious$2,500$1,750Jul 29, 2002Closed
Citation 1, item 5
29 CFR 1926.652(a)(1) · Trench protection
Serious$2,500$1,750Jul 29, 2002Closed

Inspection 124422320 OPENED APR 18, 1996Closed

Unprogrammed other · Complete · Safety · Local government · 3 employees at the site · Closed Aug 23, 1996

Main St, Barre, VT 05641 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(j)(2) · Excavations
Other-than-serious$1,500$0May 3, 1996Closed
Citation 1, item 2
29 CFR 1926.651(j)(2) · Excavations
Serious$1,500$500May 3, 1996Closed
Citation 1, item 3
29 CFR 1926.1053(b)(16) · Ladders in construction
Other-than-serious$450$0May 3, 1996Closed
Citation 2, item 1
29 CFR 1926.601(b)(5) · Motor vehicles
Other-than-serious$0$0May 3, 1996Closed
3 older inspections

Inspection 111720710 OPENED NOV 18, 1992Closed

Referral · Partial · Health · Local government · 28 employees at the site · Closed May 12, 1993

12 North Main St., Barre, VT 05641 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1030(c)(1)(iib) · Bloodborne pathogens
Other-than-serious$0$0Dec 9, 1992Closed

Inspection 3293982 OPENED MAY 11, 1987Closed

Planned · Complete · Safety · Local government · 3 employees at the site · Closed Jun 22, 1987

Washington Street, Barre, VT 05641 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(c) · Trench protection
Serious$420$300May 20, 1987Closed
Citation 2, item 2
29 CFR 1926.602(a)(2)(i) · Earthmovers and forklifts in construction
Other-than-serious$0$0May 20, 1987Closed
Citation 2, item 3
29 CFR 1926.651(i)(1) · Excavations
Other-than-serious$0$0May 20, 1987Closed
Citation 2, item 4
29 CFR 1926.652(h) · Trench protection
Other-than-serious$0$0May 20, 1987Closed

Inspection 3288339 OPENED JUL 31, 1985Closed

Planned · Complete · Safety · 100 employees at the site · Closed Dec 2, 1985

Main St, Barre, VT 05641 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Serious$150$150Aug 26, 1985Closed
Citation 1, item 2a
29 CFR 1910.27(d)(2) · Fixed ladders
Serious$250$150Aug 26, 1985Closed
Citation 1, item 2b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3a
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$200$100Aug 26, 1985Closed
Citation 1, item 3b
29 CFR 1910.134(b)(1) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3c
29 CFR 1910.134(b)(3) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3d
29 CFR 1910.134(b)(5) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3e
29 CFR 1910.134(b)(7) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3f
29 CFR 1910.134(b)(9) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3g
29 CFR 1910.134(e)(3) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3h
29 CFR 1910.134(e)(5) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 3i
29 CFR 1910.134(f)(2)(iv) · Respiratory protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 4a
29 CFR 1910.151(c) · First aid and eyewash
Serious$150$150Aug 26, 1985Closed
Citation 1, item 4b
29 CFR 1910.133(a)(1) · Eye and face protection
Serious$0$0Aug 26, 1985Closed
Citation 1, item 5
29 CFR 1910.212(a)(5) · Machine guarding
Serious$150$150Aug 26, 1985Closed
Citation 1, item 6a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$200$100Aug 26, 1985Closed
Citation 1, item 6b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Aug 26, 1985Closed
Citation 1, item 7a
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$350$200Aug 26, 1985Closed
Citation 1, item 7b
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Aug 26, 1985Closed
Citation 2, item 1
29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 2
29 CFR 1910.25(d)(2)(viii) · Portable wood ladders
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 3
29 CFR 1910.27(d)(3) · Fixed ladders
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 4
29 CFR 1910.36(b)(4) · Exit route design
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 5
29 CFR 1910.36(d)(2) · Exit route design
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 6
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 7
29 CFR 1910.37(q)(2) · Exit routes
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 8
29 CFR 1910.106(d)(5)(i) · Flammable liquids
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 9
29 CFR 1910.106(g)(3)(iii) · Flammable liquids
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 10
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 11 Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 12
29 CFR 1910.141(g)(2) · Sanitation
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 13
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 14
29 CFR 1910.157(c)(5) · Portable fire extinguishers
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 15
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 16
29 CFR 1910.157(e)(5) · Portable fire extinguishers
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 17
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 18
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 19
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 20
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 21
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 22
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 23
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 24
29 CFR 1910.304(f)(5)(v) · Grounding and circuit protection
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 25
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 26
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 27
29 CFR 1910.305(g)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 28
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 29
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Aug 26, 1985Closed
Citation 2, item 30
29 CFR 1910.305(j)(4)(iie) · Electrical wiring methods
Other-than-serious$0$0Aug 26, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1030 · Bloodborne pathogens

29 CFR 1910.1030(c)(1)(iib)

(B) The schedule and method of implementation for paragraphs (d) Methods of Compliance, (e) HIV and HBV Research Laboratories and Production Facilities, (f) Hepatitis B Vaccination and Post-Exposure Evaluation and Follow-up, (g) Communication of Hazards to Employees, and (h) Recordkeeping, of this standard, and

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(5)(i)

(5) Storage inside building—(i) Egress. Flammable liquids, including stock for sale, shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.

29 CFR 1910.106(g)(3)(iii)

(iii) Emergency power cutoff. A clearly identified and easily accessible switch(es) or a circuit breaker(s) shall be provided at a location remote from dispensing devices, including remote pumping systems, to shut off the power to all dispensing devices in the event of an emergency.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.244 · Other portable tools and equipment

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.27 · Fixed ladders

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.21 · Construction safety training

29 CFR 1926.601 · Motor vehicles

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other site preparation contractors employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.