Inspection 348968330 OPENED MAY 27, 2026Closed
156 Sweeten Creek Road, Biltmore Forest, NC 28803 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Forest City, North Carolina · Commercial and Institutional Building Construction · NAICS 236220
OSHA has inspected Clark Construction Services, Inc. 4 times in North Carolina since 2005.
The latest one began on May 27, 2026 as a planned inspection, in Biltmore Forest.
Those inspections ended with 13 citation items: 13 serious.
Penalties were first proposed at $8,550 and now stand at $7,710, 10% lower after settlements or reviews.
Fall protection in construction comes up most often in these citations: 5 items under 1926.501.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Clark Construction Services, Inc. averages $5,460 (1 cited inspection).
North Carolina · latest 90 days of OSHA records
237employers cited
6 of them in the same industry
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Clark Construction Services, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company156 Sweeten Creek Road, Biltmore Forest, NC 28803 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1825 Williams Road, Monroe, NC 28110 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $2,100 | $1,365 | Mar 11, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $2,100 | $1,365 | Mar 11, 2019 | Final |
| Citation 1, item 3b 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $0 | $1,365 | Mar 11, 2019 | Final |
| Citation 1, item 4 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $2,100 | $1,365 | Mar 11, 2019 | Final |
450 Moye Blvd, Greenville, NC 27833 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Serious | $500 | $500 | May 6, 2008 | Closed |
| Citation 1, item 2a 29 CFR 1926.150(a)(1) · Fire protection |
Serious | $150 | $150 | May 6, 2008 | Closed |
| Citation 1, item 2b 29 CFR 1926.150(c)(1)(i) · Fire protection |
Serious | $0 | $0 | May 6, 2008 | Closed |
| Citation 1, item 3a 29 CFR 1926.501(b)(2) · Fall protection in construction |
Serious | $500 | $500 | May 6, 2008 | Closed |
| Citation 1, item 3b 29 CFR 1926.501(b)(2)(ii) · Fall protection in construction |
Serious | $0 | $0 | May 6, 2008 | Closed |
| Citation 1, item 3c 29 CFR 1926.501(b)(15) · Fall protection in construction |
Serious | $0 | $0 | May 6, 2008 | Closed |
| Citation 1, item 4 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $500 | $500 | May 6, 2008 | Closed |
200 Holiday Inn Drive, Forest City, NC 28043 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.102(a)(1) · Eye and face protection in construction |
Serious | $250 | $250 | Aug 4, 2005 | Closed |
| Citation 1, item 2 29 CFR 1926.501(b)(13) · Fall protection in construction |
Serious | $350 | $350 | Aug 4, 2005 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.102(a)(1)
(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.150(a)(1)
(a) General requirements. (1) The employer shall be responsible for the development of a fire protection program to be followed throughout all phases of the construction and demolition work, and he shall provide for the firefighting equipment as specified in this subpart. As fire hazards occur, there shall be no delay in providing the necessary equipment.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.