OSHA SearchOSHA records by employer

Clarkson TN Hall: OSHA inspections and violations

Clarkson, New York · Other General Government Support · NAICS 921190

5inspections
13citation items
$0current penalties
Oct 13, 2023last inspection

Clarkson TN Hall has 5 OSHA inspections on record in New York, the first in 2015.

OSHA's last visit started on Oct 13, 2023 to follow up on an earlier case, in Clarkson.

Across those inspections OSHA issued 13 citation items: 10 serious and 3 other-than-serious.

OSHA did not attach a penalty to any of these citations.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all public administration employers the median penalty per cited inspection since 2015 is $0. Clarkson TN Hall averages $0 over 2 cited inspections in that time.

Clarkson TN Hall: OSHA citation items per year, 2015 to 2023
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

353employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Clarkson TN Hall and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347030926 OPENED OCT 13, 2023Closed

Follow-up · Partial · Safety · Local government · 5 employees at the site · Closed Oct 26, 2023

3710 Lake Rd P.o. Box 858, Clarkson, NY 14430 · Other General Government Support · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346885049 OPENED AUG 3, 2023Closed

Planned · Complete · Safety · Local government · 5 employees at the site · Closed Oct 26, 2023

3710 Lake Rd P.o. Box 858, Clarkson, NY 14430 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(a)(3) · Walking-working surfaces
Serious$0$0Sep 26, 2023Final
Citation 1, item 2
29 CFR 1910.37(b)(5) · Exit routes
Serious$0$0Sep 26, 2023Final
Citation 1, item 3
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Sep 26, 2023Final
Citation 1, item 4
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Sep 26, 2023Final
Citation 2, item 1
29 CFR 12 NYCRR PART 801.4
Other-than-serious$0$0Sep 26, 2023Final
Citation 2, item 2
29 CFR 12 NYCRR PART 801.47(A)
Other-than-serious$0$0Sep 26, 2023Final

Inspection 341056448 OPENED NOV 16, 2015Closed

Follow-up · Partial · Safety · Local government · 4 employees at the site · Closed Nov 16, 2015

3710 Lake Rd P.o. Box 858, Clarkson, NY 14430 · Other General Government Support · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340850445 OPENED AUG 12, 2015Closed

Monitoring · Partial · Safety · Local government · 4 employees at the site · Closed Aug 12, 2015

3710 Lake Rd P.o. Box 858, Clarkson, NY 14430 · Other General Government Support · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340772706 OPENED JUL 14, 2015Closed

Planned · Complete · Safety · Local government · 4 employees at the site · Closed Nov 16, 2015

3710 Lake Rd P.o. Box 858, Clarkson, NY 14430 · Other General Government Support · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 12 NYCRR PART 800.6(F)
Serious$0$0Aug 5, 2015Final
Citation 1, item 2
29 CFR 12 NYCRR PART 800.6(H)
Serious$0$0Aug 5, 2015Final
Citation 1, item 3
29 CFR 12 NYCRR PART 800.6(I)
Serious$0$0Aug 5, 2015Final
Citation 1, item 4
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Aug 5, 2015Final
Citation 1, item 5
29 CFR 1910.305(g)(1)(iv) · Electrical wiring methods
Serious$0$0Aug 5, 2015Final
Citation 1, item 6
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Serious$0$0Aug 5, 2015Final
Citation 2, item 1
29 CFR 12 NYCRR PART 800.6(E)
Other-than-serious$0$0Aug 5, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.22(a)(3)

(3) Walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes