OSHA SearchOSHA records by employer

Claudio Construction, Inc.: OSHA inspections and violations

Maplewood, New Jersey · Masonry Contractors · NAICS 238140

1inspections
8citation items
$0current penalties
Aug 6, 2015last inspection

OSHA inspectors have visited Claudio Construction, Inc. in New Jersey one time.

It opened on Aug 6, 2015 on a referral, in Maplewood.

In all, OSHA issued 8 citation items: 8 serious.

The proposed penalties came to $16,400; today they stand at $0, 100% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 4 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Claudio Construction, Inc. averages $0 across 1 cited inspection.

Claudio Construction, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

270employers cited

10 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch Claudio Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340883552 OPENED AUG 6, 2015Closed

Referral · Complete · Safety · 3 employees at the site · Closed Dec 30, 2016

1611 Springfield Avenue, Maplewood, NJ 07040 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,600$0Oct 9, 2015Final
Citation 1, item 3
29 CFR 1926.451(f)(6) · Scaffolds, general requirements
Serious$2,800$0Oct 9, 2015Final
Citation 1, item 4
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$1,600$0Oct 9, 2015Final
Citation 1, item 5
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$2,800$0Oct 9, 2015Final
Citation 1, item 6
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$2,000$0Oct 9, 2015Final
Citation 1, item 7
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$1,600$0Oct 9, 2015Final
Citation 1, item 8
29 CFR 1926.1052(b)(3) · Stairways in construction
Serious$2,400$0Oct 9, 2015Final
Citation 1, item 9
29 CFR 1926.1052(c)(4) · Stairways in construction
Serious$1,600$0Oct 9, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1052(b)(3)

(3) Treads for temporary service shall be made of wood or other solid material, and shall be installed the full width and depth of the stair.

29 CFR 1926.1052(c)(4)

(4) Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members, shall be provided between the top rail of the stairrail system and the stairway steps.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

Other masonry contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.