Inspection 341470631 OPENED MAY 5, 2016Closed
1040 North Delsea Drive, Clayton, NJ 08312 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Clayton, New Jersey · Water Supply and Irrigation Systems · NAICS 221310
Since 2016, OSHA inspectors have visited Clayton Borough Water Department in New Jersey 2 times.
The most recent inspection opened on May 5, 2016 to follow up on an earlier case, in Clayton.
In all, OSHA issued 8 citation items: 6 serious and 2 other-than-serious.
The penalties, $18,900 in total, stand where OSHA first set them.
The rule cited most here is 1910.37 (exit routes), 2 times.
Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Clayton Borough Water Department averages $18,900 across 1 cited inspection.
New Jersey · latest 90 days of OSHA records
255employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Clayton Borough Water Department and get notified the morning OSHA posts a new citation for it.
Watch this company1040 North Delsea Drive, Clayton, NJ 08312 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1040 North Delsea Drive, Clayton, NJ 08312 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Serious | $2,800 | $2,800 | Mar 28, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.37(b)(2) · Exit routes |
Serious | $2,100 | $2,100 | Mar 28, 2016 | Final |
| Citation 1, item 3 29 CFR 1910.37(b)(5) · Exit routes |
Serious | $2,800 | $2,800 | Mar 28, 2016 | Final |
| Citation 1, item 4 29 CFR 1910.176(b) · Material storage and aisles |
Serious | $2,800 | $2,800 | Mar 28, 2016 | Final |
| Citation 1, item 5 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $3,500 | $3,500 | Mar 28, 2016 | Final |
| Citation 1, item 6 29 CFR 1910.334(a)(3)(ii) · Using electrical equipment |
Serious | $3,500 | $3,500 | Mar 28, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Other-than-serious | $700 | $700 | Mar 28, 2016 | Final |
| Citation 2, item 2 29 CFR 1926.21(b)(2) · Construction safety training |
Other-than-serious | $700 | $700 | Mar 28, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(6)(i)
(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.
29 CFR 1910.176(b)
(b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.
29 CFR 1910.303(g)(2)(i)
(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.