Inspection 343595609 OPENED NOV 7, 2018Closed
Riverside Dr., Clayton, NY 13624 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2018, OSHA inspectors have visited Clayton Vill Riverside DR. Pump Station in New York 2 times.
The most recent inspection opened on Nov 7, 2018 to follow up on an earlier case, in Clayton.
In all, OSHA issued 3 citation items: 3 serious.
No penalty came with these citations.
Among utility employers, the typical cited inspection since 2015 ends with a $0 penalty. Clayton Vill Riverside DR. Pump Station averages $0 across 1 cited inspection.
New York · latest 90 days of OSHA records
376employers cited
4 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Clayton Vill Riverside DR. Pump Station and get notified the morning OSHA posts a new citation for it.
Watch this companyRiverside Dr., Clayton, NY 13624 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Riverside Dr., Clayton, NY 13624 · Sewage Treatment Facilities · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $0 | $0 | Oct 24, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.219(c)(2) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Oct 24, 2018 | Final |
| Citation 1, item 3 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $0 | $0 | Oct 24, 2018 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.212(a)(5)
(5) Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half ( 1/2) inch.
29 CFR 1910.303(g)(2)(i)
(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.