Inspection 342676392 OPENED OCT 6, 2017Closed
221 West 29th St., New York, NY 10001 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 2008, OSHA inspectors have visited CM & Associates Construction Management, LLC. in New York 6 times.
The most recent inspection opened on Oct 6, 2017 after a complaint, in New York.
In all, OSHA issued 12 citation items: 10 serious, 1 repeat and 1 other-than-serious.
The proposed penalties came to $125,029; today they stand at $84,300, 33% less.
The rule cited most here is 1926.451 (scaffolds, general requirements), 5 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. CM & Associates Construction Management, LLC. averages $27,167 across 3 cited inspections.
New York · latest 90 days of OSHA records
360employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch CM & Associates Construction Management, LLC. and get notified the morning OSHA posts a new citation for it.
Watch this company221 West 29th St., New York, NY 10001 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
626 Driggs Avenue, Brooklyn, NY 11211 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $11,408 | $9,286 | Nov 14, 2017 | Final |
| Citation 1, item 2 29 CFR 1926.451(b)(2) · Scaffolds, general requirements |
Serious | $11,408 | $0 | Nov 14, 2017 | Final |
| Citation 1, item 3 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $11,408 | $9,286 | Nov 14, 2017 | Final |
| Citation 1, item 4 29 CFR 1926.451(f)(9) · Scaffolds, general requirements |
Serious | $11,408 | $9,286 | Nov 14, 2017 | Final |
| Citation 1, item 5 29 CFR 1926.451(g)(1) · Scaffolds, general requirements |
Serious | $11,408 | $9,286 | Nov 14, 2017 | Final |
| Citation 1, item 6 29 CFR 1926.454(c) · Scaffold training |
Serious | $11,408 | $9,286 | Nov 14, 2017 | Final |
| Citation 1, item 7 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $11,408 | $9,285 | Nov 14, 2017 | Final |
| Citation 1, item 8 29 CFR 1926.503(c)(3) · Fall protection training in construction |
Serious | $11,408 | $9,285 | Nov 14, 2017 | Final |
626 Driggs Ave, Brooklyn, NY 11211 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(4)(ii) · Fall protection in construction |
Other-than-serious | $8,149 | $5,092 | Mar 15, 2017 | Final |
221 West 29th Street., New York, NY 10001 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 3a 29 CFR 1926.502(i)(3) · Fall protection systems |
Serious | $11,408 | $11,408 | Mar 15, 2017 | Final |
| Citation 1, item 3b 29 CFR 1926.502(i)(4) · Fall protection systems |
Serious | $11,408 | $0 | Mar 15, 2017 | Final |
75 Clinton Street, Brooklyn, NY 11201 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
50 Franklin Street, New York, NY 10013 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Repeat | $2,800 | $2,800 | Apr 4, 2008 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(b)(2)
(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.