OSHA SearchOSHA records by employer

CMC Custom Framing LLC: OSHA inspections and violations

Saratoga Springs, Utah · Framing Contractors · NAICS 238130

5inspections
12citation items
$3,750current penalties
Jun 3, 2015last inspection

CMC Custom Framing LLC has 5 OSHA inspections on record in Utah, the first in 2009.

OSHA's last visit started on Jun 3, 2015 as a planned inspection, in Saratoga Springs.

Across those inspections OSHA issued 12 citation items: 9 serious and 3 other-than-serious.

OSHA proposed $8,050 in penalties. After settlements and reviews the total is $3,750, down 53%.

Most often, OSHA cited 1926.501, fall protection in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. CMC Custom Framing LLC averages $1,125 over 2 cited inspections in that time.

CMC Custom Framing LLC: OSHA citation items per year, 2009 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch CMC Custom Framing LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340679893 OPENED JUN 3, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Feb 18, 2016

138 Honeysuckle Dr, Saratoga Springs, UT 84045 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(a) · Electrical equipment on job sites
Serious$1,500$1,500Jul 15, 2015Final
Citation 1, item 1b
29 CFR 1926.403(b)(1) · Electrical equipment on job sites
Serious$0$0Jul 15, 2015Final
Citation 1, item 1c
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Serious$0$0Jul 15, 2015Final
Citation 1, item 1d
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Jul 15, 2015Final

Inspection 340669498 OPENED MAY 28, 2015Closed

Planned · Partial · Safety · 5 employees at the site · Closed Sep 10, 2015

Lot 608 Valley View Ranch, Eagle Mountain, UT 84043 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$750Jul 9, 2015Final

Inspection 316936525 OPENED OCT 9, 2013Closed

Planned · Partial · Safety · 4 employees at the site · Closed Oct 9, 2013

Lot 212 Northgate, Saratoga Springs, UT 84043 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 314189994 OPENED JUL 9, 2010Open

Planned · Partial · Safety · 4 employees at the site · Open

350 W Pacific Dr, American Fork, UT 84003 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$2,000$1,000Sep 7, 2010Open
Citation 2, item 1
29 CFR 1926.502(b)(1) · Fall protection systems
Other-than-serious$250$125Sep 7, 2010Open
Citation 2, item 2a
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$250$125Sep 7, 2010Open
Citation 2, item 2b
29 CFR 1926.1053(b)(13) · Ladders in construction
Other-than-serious$0$0Sep 7, 2010Open

Inspection 312408982 OPENED MAY 13, 2009Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 17, 2009

1710 W 100s, Lehi, UT 84043 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$147Jun 4, 2009Closed
Citation 1, item 1b
29 CFR 1926.502(a)(2) · Fall protection systems
Serious$0$0Jun 4, 2009Closed
Citation 1, item 2
29 CFR 1926.503(c)(3) · Fall protection training in construction
Serious$1,050$103Jun 4, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1053(b)(13)

(13) The top or top step of a stepladder shall not be used as a step.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(a)

(a) Approval. All electrical conductors and equipment shall be approved.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction