Cna Plastering, Inc.: OSHA inspections and violations

Warwick, Rhode Island · Drywall and Insulation Contractors · NAICS 238310

1inspections
3citation items
$2,652current penalties
Aug 23, 2019last inspection

Cna Plastering, Inc. has one OSHA inspection on record in Rhode Island.

OSHA opened it on Aug 23, 2019, in Warwick.

From that inspection OSHA issued 3 citation items: 3 serious.

OSHA proposed $3,789 in penalties. After settlements and reviews the total is $2,652, down 30%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Cna Plastering, Inc. averages $2,652 over 1 cited inspection in that time.

Cna Plastering, Inc.: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

84employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch Cna Plastering, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344297460 OPENED AUG 23, 2019Closed

Unprogrammed other · Partial · Safety · 15 employees at the site · Closed Jan 6, 2020

3595 Post Rd., Warwick, RI 02886 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$3,789$2,652Oct 9, 2019Final
Citation 1, item 1b
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$0$0Oct 9, 2019Final
Citation 1, item 1c Serious$0$0Oct 9, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(b)(2)

(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(1)(iii)(c)

(C) Where run through doorways, windows, or similar openings, except as permitted in paragraph (a)(2)(ii)(I) of this section;