Inspection 346203250 OPENED SEP 8, 2022Closed
120 Mckinley St, South Plainfield, NJ 07080 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Parsippany, New Jersey · Masonry Contractors · NAICS 238140
OSHA has inspected Coastal Concrete Services LLC 2 times in New Jersey since 2019.
The latest one began on Sep 8, 2022 as a planned inspection, in South Plainfield.
Those inspections ended with 4 citation items: 4 serious.
Penalties were first proposed at $15,912 and now stand at $10,000, 37% lower after settlements or reviews.
Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Coastal Concrete Services LLC averages $10,000 (1 cited inspection).
New Jersey · latest 90 days of OSHA records
274employers cited
9 of them in the same industry
Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Jersey
Checking a subcontractor, a client or your own company? Watch Coastal Concrete Services LLC and get notified the morning OSHA posts a new citation for it.
Watch this company120 Mckinley St, South Plainfield, NJ 07080 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
272 County Rd 511, Parsippany, NJ 07054 · Masonry Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.451(b)(1) · Scaffolds, general requirements |
Serious | $5,304 | $3,000 | Aug 7, 2019 | Final |
| Citation 1, item 2 29 CFR 1926.451(e)(1) · Scaffolds, general requirements |
Serious | $5,304 | $3,500 | Aug 7, 2019 | Final |
| Citation 1, item 3a 29 CFR 1926.451(g)(1)(i) · Scaffolds, general requirements |
Serious | $5,304 | $3,500 | Aug 7, 2019 | Final |
| Citation 1, item 3b 29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements |
Serious | $0 | $0 | Aug 7, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.451(b)(1)
(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:
29 CFR 1926.451(e)(1)
(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.
29 CFR 1926.451(g)(1)(i)
(i) Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system;
Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.