6inspections
8citation items
$9,748current penalties
Mar 27, 2025last inspection

Cobra Anchors Corporation has 6 OSHA inspections on record in Pennsylvania, the first in 1995.

OSHA's last visit started on Mar 27, 2025 on a referral, in Temple.

Across those inspections OSHA issued 8 citation items: 4 serious and 4 other-than-serious.

OSHA proposed $12,882 in penalties. After settlements and reviews the total is $9,748, down 24%.

Most often, OSHA cited 1910.212, machine guarding (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Cobra Anchors Corporation averages $7,093 over 1 cited inspection in that time.

Cobra Anchors Corporation also files yearly injury logs with OSHA, summarized below.

It reported 2 severe injuries to OSHA since 2015.

Cobra Anchors Corporation: OSHA citation items per year, 1995 to 2025
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Cobra Anchors Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348141169 OPENED MAR 27, 2025Closed

Referral · Partial · Safety · 86 employees at the site · Closed Dec 31, 2025

504 Mt Laurel Avenue, Temple, PA 19560 · Hardware Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$9,457$7,093Aug 5, 2025Final

Inspection 305835282 OPENED FEB 11, 2003Closed

Planned · Partial · Safety · 18 employees at the site · Closed Feb 14, 2003

504 Mount Laurel Avenue, Temple, PA 19560 · Bolt, Nut, Screw, Rivet, and Washer Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305834095 OPENED OCT 1, 2002Closed

Planned · Complete · Health · 18 employees at the site · Closed Nov 1, 2002

504 Mount Laurel Avenue, Temple, PA 19560 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Oct 9, 2002Closed

Inspection 112894910 OPENED OCT 18, 2000Closed

Complaint · Partial · Safety · 50 employees at the site · Closed Oct 20, 2000

504 Mount Laurel Avenue, Temple, PA 19560 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 116203704 OPENED APR 6, 1999Closed

Planned · Partial · Safety · 60 employees at the site · Closed May 10, 1999

504 Mount Laurel Avenue, Temple, PA 19560 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,100$715Apr 14, 1999Closed
Citation 1, item 2
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$1,100$715Apr 14, 1999Closed

Inspection 123186975 OPENED APR 6, 1995Closed

Planned · Complete · Safety · 54 employees at the site · Closed May 31, 1995

504 Mount Laurel Avenue, Temple, PA 19560 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$525$525May 9, 1995Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$700$700May 9, 1995Closed
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0May 9, 1995Closed
Citation 2, item 2
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0May 9, 1995Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2023, the Temple site logged 6 recordable injuries or illnesses among about 92 workers: 6.3 per 100 full-time workers, against a median of 2.7 for its industry. Those cases cost 6 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Cobra Anchors Corporation
Temple · 2023
92 616.32.7
Cobra Anchors Corp.
Temple · 2021
91 515.32.7

Included with any plan: 3 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.

Mar 19, 2025, Temple: Amputation · amputations involving bone loss · other finger(s) n.e.c.

An employee was operating a clipper machine and contacted maintenance when they noticed the machine was not working properly. Maintenance worked on the machine. While verifying that the machine was fixed, the employee's left index finger was amputated above the first knuckle.

Feb 4, 2021, Temple: Amputation · amputations · fingertip(s)

An employee was operating a clipping machine when their left hand contacted the die of the machine, resulting in fractures to their thumb and middle finger and an index fingertip amputation.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(1)

(d) Hazard assessment and equipment selection. (1) The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). If such hazards are present, or likely to be present, the employer shall:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses