OSHA SearchOSHA records by employer

Cochise County Facilities Management: OSHA inspections and violations

Bisbee, Arizona · Facilities Support Services · NAICS 561210

3inspections
11citation items
$4,688current penalties
Jun 7, 2018last inspection

Since 2009, OSHA inspectors have visited Cochise County Facilities Management in Arizona 3 times.

The most recent inspection opened on Jun 7, 2018 on a referral, in Bisbee.

In all, OSHA issued 11 citation items: 3 serious and 8 other-than-serious.

The proposed penalties came to $6,000; today they stand at $4,688, 22% less.

The rule cited most here is 1910.305 (electrical wiring methods), 3 times.

Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,215 penalty. Cochise County Facilities Management averages $2,250 across 1 cited inspection.

Cochise County Facilities Management: OSHA citation items per year, 2009 to 2018
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

86employers cited

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Cochise County Facilities Management and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343213872 OPENED JUN 7, 2018Closed

Referral · Partial · Safety · Local government · 12 employees at the site · Closed Jan 23, 2019

1280 Naco Hwy, Bisbee, AZ 85603 · Facilities Support Services · OSHA's record · Phone and website on Google Maps

Incident on Jun 5, 2018: Employee sustains fractures in fall through pbr panel

At 9:30 a.m. on June 5, 2018, an employee was working for a county agency that provided facilities management. He was on a roof, working on a cooler. He fell through a fiberglass PBR (purlin bearing rib) panel to ground level. He sustained fractures to his leg and jaw. He was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(4) · Ladders in general industry
Serious$2,250$2,250Dec 7, 2018Final

Inspection 313554982 OPENED MAY 27, 2009Closed

Planned · Complete · Health · Local government · 20 employees at the site · Closed Jul 14, 2009

1415 E Melody Ln Building D, Bisbee, AZ 85603 · Facilities Support Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Jul 9, 2009Closed

Inspection 313555179 OPENED MAY 27, 2009Closed

Planned · Complete · Safety · Local government · 20 employees at the site · Closed Dec 10, 2009

1415 E Melody Ln Building D, Bisbee, AZ 85603 · Facilities Support Services · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(c)(1) · Woodworking machinery
Serious$1,875$1,219Sep 8, 2009Closed
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$1,875$1,219Sep 8, 2009Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Sep 8, 2009Closed
Citation 2, item 2
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Sep 8, 2009Closed
Citation 2, item 3
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Sep 8, 2009Closed
Citation 2, item 4
29 CFR 1910.213(h)(1) · Woodworking machinery
Other-than-serious$0$0Sep 8, 2009Closed
Citation 2, item 5
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Sep 8, 2009Closed
Citation 2, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Sep 8, 2009Closed
Citation 2, item 7
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Other-than-serious$0$0Sep 8, 2009Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(5)(i)

(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(c)(1)

(c) General requirements. (1) The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(b)

(b) Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Ladders in general industry

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other facilities support services employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.